Glassy Carbon Paste Electrodes for the Determination of Fructosyl Valine

Abstract: Nearly 200 million people worldwide have type-2 diabetes. Glucose sensors are routinely used for diagnosis; however, the relative amount of glycosylated hemoglobin (HbA1c) may be a better marker. A working electrode made from bare glassy carbon paste was used for sensing fructosyl valine (Fru-Val), a component of HbA1c. Amperometric measurements revealed a linear relationship between Fru-Val concentration and the sensing current. The square correlation coefficient and the sensitivity were 0.999 and 5.26 mA mM … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 25 publications
(15 reference statements)
0
15
0
Order By: Relevance
“…Detailed procedures relating to GCPE electrode fabrication are given in our previous paper [12]. The reproducibility of the electrode was shown by the stability of the peak current during cyclic voltammetry in buffer and by the background current of the amperometric response.…”
Section: Cyclic Voltammetry In Phosphate Buffer For Sensing Fru-val Cmentioning
confidence: 99%
See 2 more Smart Citations
“…Detailed procedures relating to GCPE electrode fabrication are given in our previous paper [12]. The reproducibility of the electrode was shown by the stability of the peak current during cyclic voltammetry in buffer and by the background current of the amperometric response.…”
Section: Cyclic Voltammetry In Phosphate Buffer For Sensing Fru-val Cmentioning
confidence: 99%
“…Glassy carbon paste was prepared by hand-mixing a 50/50 (w/w)% mixture of glassy carbon microparticles and mineral oil [12,14]. A bare GCPE was obtained by dropping the paste onto the ITO substrate.…”
Section: Sensing Electrode Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Electrochemical oxidation of FV on a bare glassy carbon paste electrode (GCPE) in the absence of an enzyme was reported by Chien et. al (Chien & Chou, 2010). The electrode was prepared by applying a glassy carbon microparticle paste on the ITO substrate using a baking process.…”
Section: Biosensors Based On Fructosyl Valine (Fv)mentioning
confidence: 99%
“…The supporting electrolyte was phosphate buffer (pH 7.4), the operating potential was +1.0 V (vs. Ag/AgCl) with the measurements being made at ambient temperature. Inset: Calibration curve obtained for different concentrations of FV (Chien & Chou, 2010).…”
Section: Biosensors Based On Fructosyl Valine (Fv)mentioning