2012
DOI: 10.1080/00032719.2012.673108
|View full text |Cite
|
Sign up to set email alerts
|

Glassy Carbon Electrode Modified with Citrate Stabilized Gold Nanoparticles for Sensitive Arsenic (III) Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 37 publications
0
10
0
Order By: Relevance
“…Chowdhury et al, (2007) reported the results of As(III) on a gold nanoparticle/polyaniline (PANI) modified glassy carbon electrode with detection limit of 0.4µg/L (Chowdhury et al 2007). A detection limit of 0.025µg/L, 0.047µg/L and 0.07µg/L was achieved with glassy carbon electrodes modified with gold nanoparticles (Gu et al 2013;Huang and Chen 2013;Lan et al 2012). Nano gold-crystal violet (CRV) film has been fabricated on glassy carbon electrode and indium tin oxide glass electrode.…”
Section: Gold Electrodesmentioning
confidence: 97%
“…Chowdhury et al, (2007) reported the results of As(III) on a gold nanoparticle/polyaniline (PANI) modified glassy carbon electrode with detection limit of 0.4µg/L (Chowdhury et al 2007). A detection limit of 0.025µg/L, 0.047µg/L and 0.07µg/L was achieved with glassy carbon electrodes modified with gold nanoparticles (Gu et al 2013;Huang and Chen 2013;Lan et al 2012). Nano gold-crystal violet (CRV) film has been fabricated on glassy carbon electrode and indium tin oxide glass electrode.…”
Section: Gold Electrodesmentioning
confidence: 97%
“…Colloidal gold solution was prepared according to literature reports 7, 13. It consisted to mix under stirring a gold solution at 1 mM (20 mL) and a solution of sodium citrate 38.8 mM (2 mL) during approximatively 5 min.…”
Section: Methodsmentioning
confidence: 99%
“…These features allow implementation for field measurements and arsenic content monitoring in decentralized zones 9, 10. Several electrodes including modified glassy carbon, platinum, boron‐doped diamond electrode, and mercury have been used for arsenic determination with gold being the best performing support for this purpose 7,1113. Metallic gold electrodes exhibit, however, memory effects and a decrease in electrode performance over time 1418.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, LODs in the range 0.01-0.05 ppb are presented in [26,[36][37][38][39][40][41][42] and LOD lower than 0.005 ppb in [43][44][45][46][47][48]. A number of different approaches have been used to improve the sensitivity of detection:…”
Section: As(iii) Determination By Anodic Stripping Voltammetry (Asv)mentioning
confidence: 99%