1991
DOI: 10.1109/61.85876
|View full text |Cite
|
Sign up to set email alerts
|

GIC mitigation: a neutral blocking/bypass device to prevent the flow of GIC in power systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 82 publications
(25 citation statements)
references
References 0 publications
0
24
0
1
Order By: Relevance
“…This effect is known as half-cycle saturation. Therefore capacitor in series for preventing dc currents or other appended resistance for decreasing dc currents installed in the neutral of transformers is the principle of [5] some neutrals blocking devices Transformers of different core and winding configurations respond differently to DC bias for providing various conducting paths for DC flux. Some research and experiments on small models testify some conclusions 6[1[71.Three-phase five-legged core form transformers are strongly susceptible because the fourth and fifth limbs provide the loop for DC flux.…”
Section: Analysis Of Tolerated DC Currents Of Transformersmentioning
confidence: 99%
“…This effect is known as half-cycle saturation. Therefore capacitor in series for preventing dc currents or other appended resistance for decreasing dc currents installed in the neutral of transformers is the principle of [5] some neutrals blocking devices Transformers of different core and winding configurations respond differently to DC bias for providing various conducting paths for DC flux. Some research and experiments on small models testify some conclusions 6[1[71.Three-phase five-legged core form transformers are strongly susceptible because the fourth and fifth limbs provide the loop for DC flux.…”
Section: Analysis Of Tolerated DC Currents Of Transformersmentioning
confidence: 99%
“…Jedno od mogućih rešenja predviđa ugradnju kondenzatora u neutralnu tačku energetskog transformatora [13]. Kondenzator blokira kvazi-DC struju (GIC), istovremeno obezbeđujući niskoomsku spregu neutralne tačke sa sistemom uzemljenja.…”
Section: Slika 3 -Uz Objašnjenje Uticaja DC Struje Na Talasniunclassified
“…To inhibit the adverse effects of GIC on the power system, At present, there are three kinds of control measures which mainly used [4][5][6]. (1)Compensation measures: in series with a DC voltage source on the transformer neutral point, by controlling the size of the output DC current and direction of it, in order to offset the original geomagnetic induced current;…”
Section: Introductionmentioning