2022
DOI: 10.1159/000527120
|View full text |Cite
|
Sign up to set email alerts
|

Gestational Age-Adjusted Reference Ranges for Fetal Left Ventricle Longitudinal Strain by Automated Cardiac Motion Quantification between 24 and 37 Weeks’ Gestation

Abstract: Introduction: The objective of this study was to construct gestational age (GA) based reference values for left ventricle (LV) longitudinal strain in normal fetuses, between 24-37 weeks’ gestation, assessing its feasibility and reproducibility, with automated cardiac motion quantification software (aCMQ-QLab) widely used in postnatal echocardiography. Methods: Prospective study including healthy gravid women with singleton pregnancies and no evidence of fetal structural cardiovascular disease. Fetal echocardi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(16 citation statements)
references
References 52 publications
1
13
0
Order By: Relevance
“…Our results also showed differences in strain behavior between groups throughout gestation. AGA fetuses had the expected behavior when compared to previously published normal values [ 41 ], remaining stable or decreasing slightly as gestation progressed. In the AGA group, GLO, middle, and apical segments showed progressive decline as GA advanced, whereas the basal segments remained stable throughout gestation.…”
Section: Resultssupporting
confidence: 61%
See 4 more Smart Citations
“…Our results also showed differences in strain behavior between groups throughout gestation. AGA fetuses had the expected behavior when compared to previously published normal values [ 41 ], remaining stable or decreasing slightly as gestation progressed. In the AGA group, GLO, middle, and apical segments showed progressive decline as GA advanced, whereas the basal segments remained stable throughout gestation.…”
Section: Resultssupporting
confidence: 61%
“…Specialized obstetricians with experience in fetal cardiology imaging and placental dysfunction performed image acquisition. Stringent criteria for ultrasound acquisition were followed according to previously published recommendations [ 41 ]. Care was taken to optimize image quality and acquire images with >80 Hz frames per second (fps).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations