Geometric calibration for a dual tube/detector micro‐CT system

Abstract: The authors describe a dual tube/detector micro-computed tomography (micro-CT) system that has the potential to improve temporal resolution and material contrast in small animal imaging studies. To realize this potential, it is necessary to precisely calibrate the geometry of a dual micro-CT system to allow the combination of projection data acquired with each individual tube/detector in a single reconstructed image. The authors present a geometric calibration technique that uses multiple projection images acq… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
56
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 56 publications
(56 citation statements)
references
References 29 publications
(33 reference statements)
0
56
0
Order By: Relevance
“…Effects of yshifts are not clearly visible either. Many methods for the estimation of geometrical parameters of cone-beam scanners have been proposed since 1990 [20, [26][27][28][29][30]. These techniques have generally fallen into two categories: those based on iterative nonlinear optimization [26,27] and those based on the direct solution of geometric equations [20,28,29,31].…”
Section: Misalignment Correction In Single Bed Acquisitionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Effects of yshifts are not clearly visible either. Many methods for the estimation of geometrical parameters of cone-beam scanners have been proposed since 1990 [20, [26][27][28][29][30]. These techniques have generally fallen into two categories: those based on iterative nonlinear optimization [26,27] and those based on the direct solution of geometric equations [20,28,29,31].…”
Section: Misalignment Correction In Single Bed Acquisitionsmentioning
confidence: 99%
“…In [27][28][29][30], either the design of this calibration object or its positioning, or both, required very high precision. Contrarily, in [20,32] the authors propose methods that avoid strict requirements on the object shape and positioning.…”
Section: Misalignment Correction In Single Bed Acquisitionsmentioning
confidence: 99%
“…We have recently introduced a geometric calibration method for the dual tube/detector system, which allows combinations of projections from the two detectors in a single reconstruction for faster dynamic scanning. 17 Due to our dual imaging chains, projection data have to be acquired only over a 90°+ fan angle, rotation. The fan angle for our system is 6.27°.…”
Section: Iia Imaging Systemmentioning
confidence: 99%
“…This involves a geometric calibration procedure presented in [7] . In essence, the geometric calibration is achieved by scanning a calibration phantom with metallic beads and computing the projections matrices required by the reconstruction.…”
Section: Geometric Calibrationmentioning
confidence: 99%