2005
DOI: 10.1259/dmfr/31342245
|View full text |Cite
|
Sign up to set email alerts
|

Geometric accuracy of the NewTom 9000 Cone Beam CT

Abstract: The digital volume tomographies of NewTom 9000 present images which are geometrically correct and, from a geometrical point of view, suitable for three-dimensional implant planning.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
109
0
30

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 195 publications
(140 citation statements)
references
References 10 publications
1
109
0
30
Order By: Relevance
“…For convenience and practical reasons, the geometrical ground truth is very often a software or hardware phantom [10][11][12][13], possibly abstract in shape, or a dry cadaver [14]. Studies on cadavers with soft tissue [15][16][17][18] are more elaborate, and are practically limited to a feasible number of measurements, especially if these are to be processed manually.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For convenience and practical reasons, the geometrical ground truth is very often a software or hardware phantom [10][11][12][13], possibly abstract in shape, or a dry cadaver [14]. Studies on cadavers with soft tissue [15][16][17][18] are more elaborate, and are practically limited to a feasible number of measurements, especially if these are to be processed manually.…”
Section: Introductionmentioning
confidence: 99%
“…Marmulla et al built an abstractly shaped test cube with accurately known reference points, and assessed the 3D deviations for 172 corresponding -manually segmented -points in the CT data [13]. Cavalcanti et al performed two specific linear measurements in all 2D resliced CT images of 8 cadaver maxillae [18].…”
Section: Introductionmentioning
confidence: 99%
“…Measurement accuracy of CBCT can be good (within 1 pixel longitudinally and up to 2.35 pixels horizontally 60 ) with good geometric accuracy (mean deviations 0.13±0.09 mm from three co-ordinate axes 61 ). However, with increasing voxel size there can be a tendency to underestimate volumetric measurements which can become significant above 300µm 62 .…”
Section: X-raysmentioning
confidence: 95%
“…Contribuindo para a consolidação da precisão das imagens de TCFC, análises geométricas das medidas também foram analisadas em alguns estudos (Marmulla et al, 2005;Baltrick et al, 2008;Primo et al, 2012) obtendo significativos resultados.…”
Section: Variação: Examinadores E Momentosunclassified