2022
DOI: 10.3390/s22155581
|View full text |Cite
|
Sign up to set email alerts
|

Generic Chemometric Models for Metabolite Concentration Prediction Based on Raman Spectra

Abstract: Chemometric models for on-line process monitoring have become well established in pharmaceutical bioprocesses. The main drawback is the required calibration effort and the inflexibility regarding system or process changes. So, a recalibration is necessary whenever the process or the setup changes even slightly. With a large and diverse Raman dataset, however, it was possible to generate generic partial least squares regression models to reliably predict the concentrations of important metabolic compounds, such… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 19 publications
0
10
1
Order By: Relevance
“…For example, a common regression model for the pH value of all three experiments of this study could be established. However, comparable to the recent study on Raman spectroscopy by Yousefi-Darani et al [ 51 ], this demands additional workflows for spectral alignment.…”
Section: Discussionmentioning
confidence: 93%
See 2 more Smart Citations
“…For example, a common regression model for the pH value of all three experiments of this study could be established. However, comparable to the recent study on Raman spectroscopy by Yousefi-Darani et al [ 51 ], this demands additional workflows for spectral alignment.…”
Section: Discussionmentioning
confidence: 93%
“…In conclusion, despite the changes in the scattered light and fluorescence dynamics, the resulting PLS models provide a reasonable overall accuracy. Although for individual cultivation conditions the predictive performance showed shortcomings of the models, with a relative RMSE below 10%, the acceptance criterium for a transferable PLS model described by Yousefi-Darani et al [ 51 ] is met.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It stands out for its spectra's sharpness and compatibility with aqueous systems ( Li et al, 2018 ). Several studies have reported the use of Raman spectroscopy for online monitoring in CHO systems in the last few years ( Li et al, 2018 ; Santos et al, 2018 ; Feidl et al, 2019 ; Yilmaz et al, 2020 ; W Eyster et al, 2021 ; Chen et al, 2021 ; A Gibbons et al, 2022 ; Domján et al, 2022 ; Schwarz et al, 2022 ; Romann et al, 2022 ; Yousefi-Darani et al, 2022 ; Yang et al, 2024 ). The online monitoring of key process variables facilitates the development of mathematical feedback models where operating conditions can be adjusted to obtain the maximum yield in protein production.…”
Section: Cho Cells Systemmentioning
confidence: 99%
“…By detecting this light, the concentration of specific molecules can be measured. In previous studies, Raman measurement systems were developed for primary medium components and metabolite concentrations, including glucose, lactate, and amino acids 12 , 13 . Additionally, feedback control systems have been established to achieve optimal concentrations 14 17 .…”
Section: Introductionmentioning
confidence: 99%