2017
DOI: 10.1016/j.epsr.2016.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Generation following with thermostatically controlled loads via alternating direction method of multipliers sharing algorithm

Abstract: Abstract-A fundamental requirement of the electric power system is to maintain a continuous and instantaneous balance between generation and load. The intermittency and uncertainty introduced by renewable energy generation requires expanded ancillary services to maintain this balance. In this paper, we examine the potential of thermostatically controlled loads (TCLs), such as refrigerators and electric water heaters, to provide generation following services in real-time energy markets (1 to 5 minutes). To cont… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 39 publications
0
16
0
Order By: Relevance
“…usage by up to 30% [2]. Such intelligent systems can improve the efficiency of building operations, better regulate indoor conditions to improve air quality and occupant comfort, and enable buildings to participate in demand response services to improve power grid stability and reduce energy related carbon emissions [3][4][5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…usage by up to 30% [2]. Such intelligent systems can improve the efficiency of building operations, better regulate indoor conditions to improve air quality and occupant comfort, and enable buildings to participate in demand response services to improve power grid stability and reduce energy related carbon emissions [3][4][5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…The sign conventions in (1) assume that the TCL is providing a cooling load and that P (and thus θ 2 ) is negative.…”
Section: Paper Outlinementioning
confidence: 99%
“…The advantages of responsive TCLs over large storage technologies include: (i) they are already wellestablished technologies; (ii) they are spatially distributed around the power system; (iii) they employ simple and fast local actuation; (iv) they are unimpaired by the outage of individuals in the population; and (v) they -on the aggregate -can produce a quasi-continuous response despite the discrete nature of the individual controls [1][2] [3].…”
Section: A Background and Motivationmentioning
confidence: 99%
See 1 more Smart Citation
“…Power withdrawals due to uncontrollable loads (lights, plug loads) are considered deterministic, inflexible, and inelastic. We do not model thermostatically controlled loads or smart inverters, though those can be added to the formulation using the approaches in [39] and [26] respectively.…”
Section: B Controllable Dersmentioning
confidence: 99%