1999
DOI: 10.1299/kikaia.65.1038
|View full text |Cite
|
Sign up to set email alerts
|

Generation and Detection of Longitudinal Wave in Steel Wires by Electromagnetic Acoustic Transducers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…The EMAT is composed of an electromagnet surrounding the sheet, which can generate a static magnetic field along the axis direction of the sheet, and an electromagnetic induction coil which can generate a dynamic magnetic field along the axis direction of the sheet. A compound magnetic field can oscillate along the axis direction of the sheet, which is needed to generate a Lamb wave travelling along the long direction in the sheet [3][4][5][6][7]. …”
Section: Drive Principle Of a Lamb Wave Into A Rectangle-shape Sheet mentioning
confidence: 99%
“…The EMAT is composed of an electromagnet surrounding the sheet, which can generate a static magnetic field along the axis direction of the sheet, and an electromagnetic induction coil which can generate a dynamic magnetic field along the axis direction of the sheet. A compound magnetic field can oscillate along the axis direction of the sheet, which is needed to generate a Lamb wave travelling along the long direction in the sheet [3][4][5][6][7]. …”
Section: Drive Principle Of a Lamb Wave Into A Rectangle-shape Sheet mentioning
confidence: 99%
“…That is, the system can inspect at high speed using a multichannel pulser and receiver equipment. However, the experimental results using a single pulser and receiver system are indicated on the paper [16] [17] [18].…”
Section: Fundamental Idea Of a Trial Guide Wave Transmitter And Receimentioning
confidence: 99%
“…When these EMATs are driven, an interference in the thickness direction and the circumferential direction can be generated. As a result, the F-mode guide wave may be injected [4]. For the developed system, it has been determined to evaluate whether or not there are advantages of not using the coupling medium of an EMAT.…”
Section: Fundamental Idea Of a Trial Guide Wave Systemmentioning