2010
DOI: 10.1103/physreva.82.013837
|View full text |Cite
|
Sign up to set email alerts
|

Generalized theory of double-resonance optical pumping ofHe4

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…where I(z 0 ) is the initial light intensity incident on ∆z, n is the numbers density of the metastable 4 He atoms, Q A is the absorption cross section, Q M is the (dichroic) monitoring cross section, J z is the polarization in the volume element [12,27]. The optical absorption of the polarized 4 He atoms in the cell gradually weakens along the light-propagation direction z.…”
Section: Theoretical Analysis and Simulationmentioning
confidence: 99%
“…where I(z 0 ) is the initial light intensity incident on ∆z, n is the numbers density of the metastable 4 He atoms, Q A is the absorption cross section, Q M is the (dichroic) monitoring cross section, J z is the polarization in the volume element [12,27]. The optical absorption of the polarized 4 He atoms in the cell gradually weakens along the light-propagation direction z.…”
Section: Theoretical Analysis and Simulationmentioning
confidence: 99%
“…Helmholtz coil were used to apply alternating magnetic fields to 4 He atoms. When the frequency of the alternating magnetic fields is equal to the Larmor frequency, NMR occurs and the depolarization process is induced [15][16][17]. In the process of depolarization, transition between adjacent energy levels causes the magnetic moment of atoms to lose its orientation, as shown in Fig.…”
Section: A Operating Principle and Sensitivity Of Optically Pumped Magnetic Field Sensormentioning
confidence: 99%
“…In (15), K1 is gyromagnetic ratio, K1=28.02356, K2 is coefficient of photoelectric to voltage, K2=0.9×190×1000, K3 is magnification of pre-amplifier and filter, K3=10×510×5, K4 and K5 are amplification of AD convertor and phase-locked amplifier, respectively, K4=2 18 /5, K5= 1.3563×1.8118. K6 andK7 are coefficient of frequency modulator and coils-control circuit, respectively, K6=(14000×2π×10)/(49999872×2 48 ), K7=12/3.3.…”
Section:       -1 1 2 3 4 -3 2 3 4 5 6 K K K K Z D Z H Z = 1 + K K K K K Z D Z (15)mentioning
confidence: 99%
“…As mentioned above, 4 He atomic energy level transition between the meta-state and excited-state obtain energy through the absorption of light in the certain wavelengths [11]. Because of optical pumping action, there are three transitions during wavelength range of 1083.1 nm around to 1083.3 nm around, form the transition line D 0 , D 1 and D 2 , respectively [12]. Part of the light and electrical signal curve changing with time during the voltage scanning process can be showed in Figure 3.…”
Section: S353mentioning
confidence: 99%