Generalized EPID calibration for in vivo transit dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
22
0
2

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 28 publications
(24 citation statements)
references
References 20 publications
0
22
0
2
Order By: Relevance
“…In this context, the strength of our method is twofold. First of all, our method adopts a generalized algorithm that can be easily implemented with a minimal workload for all Varian, Elekta and Siemens linacs and related EPIDs, with a few commissioning measurements time reduced to less than 30 minutes per linac [14,16]. Secondly, the software is interfaced with the Record&Verify system of the radiotherapy unit, allowing a direct and fast access to EPID images and treatment planning network.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this context, the strength of our method is twofold. First of all, our method adopts a generalized algorithm that can be easily implemented with a minimal workload for all Varian, Elekta and Siemens linacs and related EPIDs, with a few commissioning measurements time reduced to less than 30 minutes per linac [14,16]. Secondly, the software is interfaced with the Record&Verify system of the radiotherapy unit, allowing a direct and fast access to EPID images and treatment planning network.…”
Section: Discussionmentioning
confidence: 99%
“…In recent years, the authors developed a generalized procedure for the isocenter dose reconstruction of 3D-CRT treatments (Diso), based on the correlation functions between EPID transit signals and the doses at phantom mid-plane [11][12][13][14][15]. This research led to the foundation of an Italian national project financed by the Istituto Nazionale di Fisica Nucleare (INFN) and the Diso software was extensively applied in clinical routine in several Italian centers.…”
Section: Introductionmentioning
confidence: 99%
“…Researchers from Universita Cattolica del Sacro Cuore, Rome, Italy, proposed a generic measurement-based model but the method was only for single point comparisons, which may not be suitable for IMRT verifications [36][37][38][39][40]. Although the model was later extended by Peca and Brown 41 to perform 2D verification, it was only tested for 3D conformal fields.…”
mentioning
confidence: 98%
“…These effects are generally quantified in terms of the measured signal after the end of irradiation [2] [5] [7]- [9] [17] [18] [27]. S R is meaningful with equilibrium indices more than unity.…”
Section: The Residual Signalmentioning
confidence: 99%
“…Nevertheless, many recent publications [9] [13] discuss the use of EPID as in vivo dosimeters giving an impression of a well-established EPID characterization and calibration. In many of these publications, the manufacturer definition of the integrated image has been used to represent the EPID signal.…”
mentioning
confidence: 99%