2016
DOI: 10.1049/joe.2016.0045
|View full text |Cite
|
Sign up to set email alerts
|

Generalised analytical framework for the stability studies of an AC microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 21 publications
(29 reference statements)
0
6
0
Order By: Relevance
“…In this way, the virtual resistor is parallel connect with the filter capacitor, as in Figure 2. Based on the open-loop transfer function of LCL network, Equations (3)- (5), the relationship between the output current Ig(s) and the reference current Iref(s) of the inverter can be obtained, as Equation (6):…”
Section: Modelling Of the Inverter With Virtual Resistor Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…In this way, the virtual resistor is parallel connect with the filter capacitor, as in Figure 2. Based on the open-loop transfer function of LCL network, Equations (3)- (5), the relationship between the output current Ig(s) and the reference current Iref(s) of the inverter can be obtained, as Equation (6):…”
Section: Modelling Of the Inverter With Virtual Resistor Controlmentioning
confidence: 99%
“…With the increasing concerns of traditional energy shortage, greenhouse gas emissions, environmental pollution problem and so on, applications of microgrid become popular [1,2]. The typical microgrid system contains traditional power grid and DG (Distributed Generation) system [3][4][5]. The technology of DG system has been developed rapidly [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the phase‐locked loop (PLL) is placed across the filter capacitor terminal for the purpose of better stability and modelling convenience. The block diagram of the PLL used can be found in [30]. All the dynamic models are appropriately corrected based on the chosen dq transformation matrix.…”
Section: Case Studymentioning
confidence: 99%
“…From a voltage or current phasor, the initial values of DQ components (with respect to the global or common reference frame [7, 30]) of the corresponding voltage or current quantity are obtained through the following relationships: V¯=vDfalse(0false)normaljvQfalse(0false)3 I¯=iDfalse(0false)normaljiQfalse(0false)3…”
Section: Case Studymentioning
confidence: 99%
“…Hybrid power systems have more complex dynamics than conventional AC power systems [6][7][8] and new scenarios of instability have emerged due to the interaction among dynamics of interface converters and electromechanical dynamics. Consequently, there is a need for understanding the mechanisms that may lead hybrid power systems to instability.…”
Section: Introductionmentioning