1984
DOI: 10.1351/pac198456040479
|View full text |Cite
|
Sign up to set email alerts
|

General aspects of trace analytical methods-VI. Acid pressure decomposition in trace element analysis

Abstract: Abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

1996
1996
2024
2024

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 68 publications
(17 citation statements)
references
References 6 publications
0
17
0
Order By: Relevance
“…The autoclave system, also known as digestion bomb using polytetrafluoroethylene (PTFE) interior reinforced with steel has been widely used in digestion procedures after 1960. 14 The autoclave system was often convectively heated which enabled the digestion of large number of samples, for example in laboratory drying oven. The digestion of inorganic matrices was extensively studied 15,16 but, however, the research related to digestion of plastics was limited until the development of commercial high pressure asher (HPA) and microwave-assisted (MW-AD) digestion systems.…”
Section: Introductionmentioning
confidence: 99%
“…The autoclave system, also known as digestion bomb using polytetrafluoroethylene (PTFE) interior reinforced with steel has been widely used in digestion procedures after 1960. 14 The autoclave system was often convectively heated which enabled the digestion of large number of samples, for example in laboratory drying oven. The digestion of inorganic matrices was extensively studied 15,16 but, however, the research related to digestion of plastics was limited until the development of commercial high pressure asher (HPA) and microwave-assisted (MW-AD) digestion systems.…”
Section: Introductionmentioning
confidence: 99%
“…Allen et al (1974) used open vessels, enabling HF acid to be fumigated along with silicon, reducing matrix interferences in the subsequent analysis. More commonly sealed acid pressure vessels are used which ensure more complete dissolution (Jackwerth and Gomiscek 1984;Garçon et al 2012), but which then requires greater care in the management of matrix effects. Boric acid (H 3 BO 3 ) is added to make the solution safe.…”
Section: Extraction Methodsmentioning
confidence: 99%
“…The total metal content of the calcined samples and residues was measured after complete dissolution using a pressure decomposition system [13] as follows. A powdered sample, either the calcined sample (1/10 of the total weight) or the solid residue, was added to 12 M HCl (10 mL) in a PTFE inner vessel.…”
Section: Characterizationmentioning
confidence: 99%