2012
DOI: 10.1088/1748-0221/7/03/c03036
|View full text |Cite
|
Sign up to set email alerts
|

GEM-MSTPC: An active-target type detector in low-pressure He/CO2mixed gas

Abstract: We developed an active-target type gas counter operating with low pressure He/CO 2 (10%) detector gas for application in studying low-energy nuclear reactions using radioactive nuclear beams (RNBs). A 400-µm-thick gas electron multiplier (THGEM) was used as the proportional counter for high injection rate capability. We examined the gas gain stability and the influence of ion feedback on particle tracks at high beam injection rates of up to 10 5 particles per second (pps) using a low-energy 12 C beam. By means… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
12
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 13 publications
1
12
0
Order By: Relevance
“…By measuring the reaction Q -value leading to 9 Li that has a known mass, the mass of 11 Li could be determined with a precision of ±22 keV [45] by energy-energy and angle-angle kinematics reconstruction. The derived 11 Li two-neutron separation energy is S 2n = 363 (22) keV. This value is in good agreement with values from the MISTRAL transmission spectrometer [46] and the TITAN penning trap measurement [47] of S 2n = 378(5) keV and S 2n = 369.15(65) keV respectively.…”
Section: Mayasupporting
confidence: 83%
See 3 more Smart Citations
“…By measuring the reaction Q -value leading to 9 Li that has a known mass, the mass of 11 Li could be determined with a precision of ±22 keV [45] by energy-energy and angle-angle kinematics reconstruction. The derived 11 Li two-neutron separation energy is S 2n = 363 (22) keV. This value is in good agreement with values from the MISTRAL transmission spectrometer [46] and the TITAN penning trap measurement [47] of S 2n = 378(5) keV and S 2n = 369.15(65) keV respectively.…”
Section: Mayasupporting
confidence: 83%
“…Here the simulation is shown for 0.25 atm of D 2 gas and for a magnetic field of 2 T, in an active target device such as the AT-TPC (see Section 2.7). The figure shows that a very good [19,20] GEM-MSTPC (KEK) [21,22]. resolution can be obtained, about 200 keV (FWHM) in the invariant mass system.…”
Section: Introductionmentioning
confidence: 88%
See 2 more Smart Citations
“…A GEM-TPCbased (Gas Electron Multiplier and Time Projection Chamber) active target system is reported in refs. [1,2] where a He+CO 2 gas was used. We are developing a GEM-TPC-based gaseous active target with a pure deuterium gas, called the Center for Nuclear Study Active Target (CAT), for the purpose of measuring deuteron inelastic scattering off unstable nuclei.…”
Section: Introductionmentioning
confidence: 99%