2000
DOI: 10.1002/(sici)1097-4636(20000305)49:3<390::aid-jbm12>3.0.co;2-q
|View full text |Cite
|
Sign up to set email alerts
|

Gd3+-loaded polyion complex for pH depiction with magnetic resonance imaging

Abstract: In clinical diagnosis, gadolinium (Gd) ion/low molecular weight chelater complexes have been used as MRI contrast agents that disperse throughout a particular tissue and cause a brighter appearance in MRI. In order to provide a novel imaging concept for MRI, a contrast agent in which the T(1)-relaxation shortening activity (R(1) relaxivity) changes in response to the pH differences was studied. We prepared a polyion complex (PIC) consisting of a polyanionic Gd-chelater, poly(diethylenetriamine-N,N,N',N", N"-pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
22
0

Year Published

2000
2000
2012
2012

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 44 publications
(22 citation statements)
references
References 21 publications
(21 reference statements)
0
22
0
Order By: Relevance
“…The pH-sensitive 31 P MR resonance of 3-aminopropylphosphate (3-APP) has been used by us and other researchers to measure extracellular pH of tumors and normal tissues in mice (4,5,10). Molecules with pH-sensitive 19 F and 1 H resonances have also been reported. Ojugo et al (10) reported that pH measurements with excellent signalto-noise ratio (SNR) per time period are possible with the extracellular 19 F-containing pH probe, ZK-150471.…”
mentioning
confidence: 99%
See 4 more Smart Citations
“…The pH-sensitive 31 P MR resonance of 3-aminopropylphosphate (3-APP) has been used by us and other researchers to measure extracellular pH of tumors and normal tissues in mice (4,5,10). Molecules with pH-sensitive 19 F and 1 H resonances have also been reported. Ojugo et al (10) reported that pH measurements with excellent signalto-noise ratio (SNR) per time period are possible with the extracellular 19 F-containing pH probe, ZK-150471.…”
mentioning
confidence: 99%
“…Molecules with pH-sensitive 19 F and 1 H resonances have also been reported. Ojugo et al (10) reported that pH measurements with excellent signalto-noise ratio (SNR) per time period are possible with the extracellular 19 F-containing pH probe, ZK-150471. They list the lack of potentially interfering endogenous 19 F resonances, and the higher NMR and pH sensitivity of ZK-150471 as advantages of the 19 F probe compared to 3-APP.…”
mentioning
confidence: 99%
See 3 more Smart Citations