2008
DOI: 10.1007/s00216-008-1896-0
|View full text |Cite
|
Sign up to set email alerts
|

GC×GC-ECD: a promising method for the determination of dioxins and dioxin-like PCBs in food and feed

Abstract: There is a need for cost-efficient alternatives to gas chromatography (GC)-high-resolution mass spectrometry (HRMS) for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (PCBs) in food and feed. Comprehensive two-dimensional GC-micro electron capture detection (GC× GC-μECD) was tested and all relevant (according to the World Health Organisation, WHO) PCDD/Fs and PCBs could be separated when using a DB-XLB/LC-50 column combination. Validation… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0
3

Year Published

2009
2009
2014
2014

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 45 publications
(14 citation statements)
references
References 31 publications
(40 reference statements)
0
11
0
3
Order By: Relevance
“…Auch wenn unpolare polare Phasenkombinationen in der GC GC in der Regel bevorzugt werden, gewinnen nichtklassische Kombinationen, wie polare mäßig polare Phasen, [28] flüssigkristalline Phasen, [29] Phasen aus ionischen Flüssigkeiten [30] und enantioselektive stationäre Phasen, [31][32][33][34] an Interesse, da sie zu hohen Auflçsungen der Analyten und auch zu Trennungen chromatographischer Regionen führen kçnnen. Omais und Mitarbeiter [35]…”
Section: Methodsunclassified
“…Auch wenn unpolare polare Phasenkombinationen in der GC GC in der Regel bevorzugt werden, gewinnen nichtklassische Kombinationen, wie polare mäßig polare Phasen, [28] flüssigkristalline Phasen, [29] Phasen aus ionischen Flüssigkeiten [30] und enantioselektive stationäre Phasen, [31][32][33][34] an Interesse, da sie zu hohen Auflçsungen der Analyten und auch zu Trennungen chromatographischer Regionen führen kçnnen. Omais und Mitarbeiter [35]…”
Section: Methodsunclassified
“…Haglund et al [84] demonstrated very good results when comparing an alternative to the standard GC-HRMS (highresolution mass spectrometry) method for polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and PCBs in food and feed. Using an electron capture detector (ECD) they first tried 20 different column combinations to determine how many of a given set of target analytes could be separated.…”
Section: Foodmentioning
confidence: 95%
“…For instance, micro electroncapture detectors (mECD), typically with a 50 Hz sampling rate, have been reported as a useful alternative, specifically for the quantitative analysis and low-cost screening of polyhalogenated target compounds, such as polychlorinated paraffins, polychlorinated dibenzodioxins and dibenzofurans (PCDD/FS), and organochlorine pesticides. [18,29,56] Studies employing comprehensive GC GC systems coupled to nitrogen phosphorus detection (GC GC-NPD) demonstrated the potential and high sensitivity of NPD for the detection of nitrogen-containing substances in complex food matrices.…”
Section: Detecting Gc Gc Signals With a Sufficient Acquisition Ratementioning
confidence: 99%
“…The maximization of orthogonality of different stationary-phase combinations has been described using constants of a solvation parameter model, such as the Abraham model. [26] A separation-space evaluation method based on Denaulays triangulation algorithms was proposed by Semard et al, [27] and then further used to optimize the selection of column sets, geometric parameters of the secondary column, Even though non-polar polar column combinations are often stated as the preferred approach for GC GC, nonclassical conditions, that is, polar moderately non-polar column combinations [28] as well as liquid crystalline, [29] ionic liquid, [30] and enantioselective stationary phases, [31][32][33][34] are gaining attention and can lead to high-resolution and grouptype separations. Moreover, Omais and co-workers [35] recently suggested that the non-polar polar column combination is not a necessary condition to achieve large peak distribution in the 2D plane, and non-classical conditions can occasionally provide a large occupation of 2D space.…”
Section: Structured Separation Space In Gc Gc Chromatogramsmentioning
confidence: 99%