2007
DOI: 10.1016/j.jmr.2007.01.005
|View full text |Cite
|
Sign up to set email alerts
|

GAVA: Spectral simulation for in vivo MRS applications

Abstract: An application that provides a flexible and easy to use interface to the GAMMA spectral simulation package is described that is targeted at investigations using in vivo MR spectroscopic methods. The program makes available a number of widely used spatially-localized MRS pulse sequences and NMR parameters for commonly-observed tissue metabolites, enabling spectra to be simulated for any pulse sequence parameter and viewed in an integrated display. The application is interfaced with a database for storage of all… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
102
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 109 publications
(102 citation statements)
references
References 54 publications
0
102
0
Order By: Relevance
“…Four sets of basis spectra were simulated using the GAVA software package (24). The GAVA software was modified to yield a Lorentzian lineshape instead of its default Gaussian shape.…”
Section: Discussionmentioning
confidence: 99%
“…Four sets of basis spectra were simulated using the GAVA software package (24). The GAVA software was modified to yield a Lorentzian lineshape instead of its default Gaussian shape.…”
Section: Discussionmentioning
confidence: 99%
“…A water reference (NEX = 8) was also acquired for all datasets to be used for phase and eddy current correction. A basis set of 19 metabolites was simulated using the gamma visual analysis (GAVA) software (Soher, Young, Bernstein, Aygula, & Maudsley, 2007) for use in quantifying the 30‐ms TE MRS data: alanine, aspartate, creatine (Cr), γ‐aminobuytric acid, glucose, glutamate (Glu), glutamine (Gln), glutathione (GSH), glycine, glycerophosphocholine, lactate, myo‐inositol (mI), N‐acetylaspartate (NAA), N‐acetylaspartylglutamate, phosphocholine, phosphocreatine, phosphoroylethanolamine, scyllo‐inositol, and taurine. A basis set of eight metabolites simulated using the same software package was generated for use in quantifying 135‐ms TE data: Cr, glycerophosphocholine, lactate, mI, NAA, N‐acetylaspartylglutamate, phosphocholine, and phosphocreatine.…”
Section: Methodsmentioning
confidence: 99%
“…A water reference (NEX = 8) was collected and utilized for phasing and eddy current correction. A basis set was simulated using the GAVA software package (Soher et al, 2007) that was modified to yield a Lorentzian lineshape instead of its default Gaussian lineshape as previously reported . This basis set was imported into LCModel, an automated curve fitting software package (Provencher, 1993) for metabolite quantification.…”
Section: White Matter Mrsmentioning
confidence: 99%