“…It is recommended 1 to measure gastric emptying (GE) with a radioisotopically labeled solid meal at least at the following time points: immediately after ingestion of the meal (time 0 h) and hourly for the next 4 h. Software programs such as MIM (MIM Software Inc., version 7.14) permit the estimation of GE T-half (GE T 1/2 ) from hourly measurements. Linear interpolation of GE T 1/2 using measurements at 0, 0.5, 1, 2, 3, and 4 h, or 0, 1, 2, and 4 h demonstrated good correlations with power exponential curve measurements at 0, 1, 2, and 4 h. 2 Our aim was to compare the estimation of GE T 1/2 using linear interpolation of 2 (points above the 50% emptying mark), 4 (emptying at 0, 1, 2, and 4 h), or 8/9 time point measurements (at 0, 15, 30, and 45 min, and 1, 1.5, 2, 3, and 4 h) of intragastric content using MIM Analysis.…”