Gas holdup and mass transfer in bubble column reactors operated at elevated pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

14
138
2
4

Year Published

2002
2002
2018
2018

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 202 publications
(158 citation statements)
references
References 0 publications
14
138
2
4
Order By: Relevance
“…The two effects proving the reliability of kLa results were tested: (i) the effect of pressure step non-ideality and (ii) the effect of gas composition (air absorption and pure The correlation between volumetric mass transfer coefficient and gas holdup is presented in Figure 8 and shows good agreement with published results by several authors [12,[14][15][16], however, again at low gas flow rates only, i.e., gas holdups (u G < 0.07 m/s, ε G < 15%). At high gas flow rates (u G > 0.07 m/s), there are significant differences between the present data and the data published by other authors.…”
Section: Discussionsupporting
confidence: 79%
See 1 more Smart Citation
“…The two effects proving the reliability of kLa results were tested: (i) the effect of pressure step non-ideality and (ii) the effect of gas composition (air absorption and pure The correlation between volumetric mass transfer coefficient and gas holdup is presented in Figure 8 and shows good agreement with published results by several authors [12,[14][15][16], however, again at low gas flow rates only, i.e., gas holdups (u G < 0.07 m/s, ε G < 15%). At high gas flow rates (u G > 0.07 m/s), there are significant differences between the present data and the data published by other authors.…”
Section: Discussionsupporting
confidence: 79%
“…For correlating experimental data of kLa there are two approaches: either to express their dependency on the gas superficial velocity (more frequent) or their dependency on the gas holdup data (see the correlations [9,12,[14][15][16] in Table 1). Table 3 resumes both types of correlations and it includes also the correlation for gas holdup data and operating conditions for our measurements.…”
Section: Discussionmentioning
confidence: 99%
“…(25) largely underestimates the transition gas velocity. This observation was also made by Letzel et al (1999), who also compared their results with the correlation of Reilly et al (1994), which provide a better agreement. On the other hand, Eq.…”
Section: Flow Regime Transitionsupporting
confidence: 62%
“…Focusing on the batch mode, the typical values of U trans found in the literature for air-water systems in bubble columns of diameter greater than 0.15 m range between 0.01 and 0.08 m/s under ambient operating conditions (Dargar and Macchi, 2006;Hur et al, 2013;Krishna et al, 1991;Letzel et al, 1999;Reilly et al, 1994;Ruzicka et al, 2001;Schumpe and Grund, 1986;Urseanu, 2000;Wilkinson et al, 1992;Zahradnik et al, 1997). The value depends mainly on the sparger type.…”
Section: Flow Regime Transitionmentioning
confidence: 97%
“…Additional verification of the experimental results is performed by comparing the experimental result in the current study to literature data under similar air-water systems [19,[21][22][23][24][25][26][27][28]. Since there is limited literature data available for low L/D ratio conditions, only experimental results obtained at L/D ratio of 7.2 are used for comparison.…”
Section: Comparison To Literature Datamentioning
confidence: 92%