1966
DOI: 10.1016/0006-2952(66)90245-0
|View full text |Cite
|
Sign up to set email alerts
|

Gas-chromatographic resolution of optical isomers in microgram samples of amphetamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

1970
1970
1988
1988

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…On the other hand, gas chromatography (GC) and radioimmunoassay (RIA) have reportedly been applied [13][14][15]. For GC, however, an optically active liquid phase, which is highly heat stable, and diastereomers must be produced, and for RIA a specific antiserum against the optically different compounds is required.…”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, gas chromatography (GC) and radioimmunoassay (RIA) have reportedly been applied [13][14][15]. For GC, however, an optically active liquid phase, which is highly heat stable, and diastereomers must be produced, and for RIA a specific antiserum against the optically different compounds is required.…”
Section: Discussionmentioning
confidence: 99%
“…The isomeric purity of the (+)-and (-)-isomers of Amphet and AMPT administered to rats was determined by reacting each compound with trifluoroacetyl-(-)-prolyl chloride (Gordis, 1966). The resulting diasterioisomers were separated and estimated by methane c.i.g.c.m.s.…”
Section: Stereochemical Impuritiesmentioning
confidence: 99%
“…In addition to the earlier mentioned ready availability and stability of V, this reagent was superior to 1-111 in providing better GLC resolution in cases where comparison could be made. For example, VI (5,6), VII (13), and XI11 (14) were derivatized with reagent I; VI, VIII, and XIV were resolved with I1 (2) and I11 (3). In these cases, V tended to give better resolution and/or shorter retention times.…”
Section: XIVmentioning
confidence: 99%
“…The tube was then shaken for I0 min and centrifuged for 10 min, followed by GLC analysis of the lower organic layer as described. 6 Life Sciences gas chromatograph 2100, Varian Associates, Palo Alto, Calif. Gas International bottle shaker, International Equipment Co., Boston, Mass. Derivatization of Pure Compounds-The amine or amine salt (0.1-0.2 mg) in a conical screw-capped tube was treated with XV (50fil), V reagent solution (50 pl), and pyridine (20 pl).…”
mentioning
confidence: 99%
See 1 more Smart Citation