Gas chromatographic method for the determination of vincamine in blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
5
0

Year Published

1978
1978
2008
2008

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…The achieved LOD revealed the high sensitivity of the described SW-AdAS voltammetric method over most of the previously reported ones for determination of vincamine; (10 ng ml Ϫ1 ), 8,15) (5 ng ml Ϫ1 ), 13,14,16) (3 ng ml Ϫ1 ), 9) (0.25 mg ml Ϫ1 ) 10) and (0.05 mg ml Ϫ1 ).…”
mentioning
confidence: 66%
See 1 more Smart Citation
“…The achieved LOD revealed the high sensitivity of the described SW-AdAS voltammetric method over most of the previously reported ones for determination of vincamine; (10 ng ml Ϫ1 ), 8,15) (5 ng ml Ϫ1 ), 13,14,16) (3 ng ml Ϫ1 ), 9) (0.25 mg ml Ϫ1 ) 10) and (0.05 mg ml Ϫ1 ).…”
mentioning
confidence: 66%
“…Vinca extracts, pharmaceutical formulations, plasma and urine). These methods include spectrophotometry, [5][6][7] titrimetry, 6) selected ion monitoring, 7) gas chromatography (GC) 9,10) and liquid chromatography (LC).…”
mentioning
confidence: 99%
“…GC separation has been done on underivatized vincamine [15,16]. In the present study, a GC program was devised for the underivatized compound to allow approximately 85% of vincamine to survive the injection and column conditions.…”
Section: Derivatization Of Vincamine and Limitsof Detectionmentioning
confidence: 99%
“…Thin-layer chromatography (TLC) combined with UV reflectance spectroscopy [11] and countercurrent chromatography with thermospray mass spectrometry [12] are other techniques that also have been used to analyze vincamine. Gas chromatography (GC) analysis has been performed on both derivatized [13,14] and nonderivatized forms of vincamine [15,16] with flame ionization detector (FlO) [13], nitrogen flame ionization detector (NFID) [15,16], or selected ion electron ionization mass spectrometric detectors [14]. The electron ionization (EO mass spectrum of vincamine has been studied in great detail [13,[17][18][19].…”
mentioning
confidence: 99%
“…Although modern cell culture techniques such as those involving root and hairy root cultures afford relatively high alkaloid levels in appropriate production organisms, a higher detector sensitivity is always desirable. However, steady development work on NPD has yielded an efficient device for many analytical applicatons involving alkaloids (Vitzhum et al, 1974;Kinsun and Moulin, 1977;Severson et al, 1981;Turner et a[., 1981;Kim 1986). In the present investigation, application of a GC-NPD detector/PTV injector assembly has been compared with that of more conventional instrumentation in the analysis of some tropane alkaloids.…”
Section: Introductionmentioning
confidence: 99%