Gamma-Ray Attenuation and Exposure Buildup Factor of Novel Polymers in Shielding Using Geant4 Simulation

Abstract: Polymers are often used in medical applications, therefore, some novel polymers and their interactions with photons have been studied. The gamma-ray shielding parameters for Polymethylpentene (PMP), Polybutylene terephthalate (PBT), Polyoxymethylene (POM), Polyvinylidenefluoride (PVDF), and Polychlorotrifluoroethylene (PCTFE) polymers were determined using the Geant4 simulation and discussed in the current work. The mass attenuation coefficients (μ/ρ) were simulated at low and high energies between 0.059 and 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
32
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 64 publications
(32 citation statements)
references
References 29 publications
0
32
0
Order By: Relevance
“…The net area per unit time for each energy peak in the spectrum ( N 0 ) and ( N ) for a particular radioactive source was determined in the absence and in the presence of the tested composite sample. The characteristics of the radioactive sources used in the measurements are listed in Table 2 [ 28 , 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…The net area per unit time for each energy peak in the spectrum ( N 0 ) and ( N ) for a particular radioactive source was determined in the absence and in the presence of the tested composite sample. The characteristics of the radioactive sources used in the measurements are listed in Table 2 [ 28 , 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…The radiation shielding parameters were experimentally determined by the narrow-beam method. A high-purity germanium (HPGe) detector was used, alongside point sources of different energies in cases where their activities and other specifications could be found (Table 2) [27][28][29][30][31][32][33]. The sample was placed between the source and the detector using a collimator and lead shield.…”
Section: Methodsmentioning
confidence: 99%
“…While the relative increase between the results of the LAC of the micro and nano fillers are evaluated via the following: The intensity (I 0 ), count rate (N 0 ) or area under the peak (A 0 ) were measured for all energies in a case without the SR sample, and then the sample was placed between the source and detector and the count rate (N) or area under the peak (A) was measured at the same time. The LAC was measured experimentally using the following equation [30,31]:…”
Section: Shielding Propertiesmentioning
confidence: 99%