2020
DOI: 10.1080/07366299.2019.1710918
|View full text |Cite
|
Sign up to set email alerts
|

Gamma Radiolysis of TODGA and CyMe4BTPhen in the Ionic Liquid Tri-n-Octylmethylammonium Nitrate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 51 publications
0
12
0
Order By: Relevance
“…The use of CyMe 4 BTPhen in [A336][NO 3 ] diluent can be nonetheless justified, knowing its high stability against radiation-induced degradation. 31 In addition, distribution ratios exceeding 10 for Am( iii ) and Cm( iii ) with sufficient separation from Ln( iii ) can already be achieved within contact times no longer than 30 min (however further studies will be required to verify if such solvent can be of practical use in continuous processes). With respect to the selectivity of the system, the solvent composed of 0.01 mol L −1 CyMe 4 BTPhen in [A336][NO 3 ] clearly favors the extraction of An( iii ) over Eu( iii ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of CyMe 4 BTPhen in [A336][NO 3 ] diluent can be nonetheless justified, knowing its high stability against radiation-induced degradation. 31 In addition, distribution ratios exceeding 10 for Am( iii ) and Cm( iii ) with sufficient separation from Ln( iii ) can already be achieved within contact times no longer than 30 min (however further studies will be required to verify if such solvent can be of practical use in continuous processes). With respect to the selectivity of the system, the solvent composed of 0.01 mol L −1 CyMe 4 BTPhen in [A336][NO 3 ] clearly favors the extraction of An( iii ) over Eu( iii ).…”
Section: Resultsmentioning
confidence: 99%
“…Indeed, some types of ionic liquids proved to show a much higher stability towards ionizing radiation. 31,32 The low vapour pressure of ionic liquids renders them safer to use than the more common aliphatic diluents. In addition, the high intrinsic electrical conductivity of ionic liquids can prevent the build-up of static charge in the organic solvent, a phenomenon sometimes encountered when using molecular diluents for solvent extraction processes, which can result in re.…”
Section: Introductionmentioning
confidence: 99%
“…This study opens perspectives for future research using flexible, high dose rate pooltype gamma irradiation facilities on novel solvent extraction systems, such as newly developed diglycolamides [19,46] or ionic-liquid-based systems. [47][48][49] 2 Experimental…”
Section: = ×mentioning
confidence: 99%
“…27 Moreover, TODGA was found to have a higher radiation stability in [A336][NO3] than in aliphatic diluents. 28 The effect of replacing 2 (1,2,4-) triazine moieties by 2 (1,2,3-) triazole moieties in the case of the BTP complexants for An(III) and Ln(III) separation was demonstrated in the hydrophilic, tridentate complexant 2,6-bis[1-(propan-1-ol)-1,2,3-triazol-4-yl)]pyridine (PyTri-Diol). 21,22 It proved to be a viable CHON-compliant alternative for the previously suggested SO3-Ph-BTP molecule in the i-SANEX process.…”
Section: Introductionmentioning
confidence: 99%