2011
DOI: 10.1016/j.nima.2011.01.025
|View full text |Cite
|
Sign up to set email alerts
|

Gamma–gamma coincidence spectrometer setup for neutron activation analysis and nuclear structure studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 6 publications
0
8
0
1
Order By: Relevance
“…Two plates of 2 mm thick lead were placed between the detectors and target to decrease the number of backscattered gamma rays and to filter out X-ray. The electronics configuration was used in those gammagamma coincidence experiments are shown in Figure 1, the parameters of system were setup by method in Reference [9]. The detector signals are amplified with 572 amplifier (AMP) modules with a shaping time of 3.0 µs and about 1 keV per channel.…”
Section: The Experimental Arrangementmentioning
confidence: 99%
“…Two plates of 2 mm thick lead were placed between the detectors and target to decrease the number of backscattered gamma rays and to filter out X-ray. The electronics configuration was used in those gammagamma coincidence experiments are shown in Figure 1, the parameters of system were setup by method in Reference [9]. The detector signals are amplified with 572 amplifier (AMP) modules with a shaping time of 3.0 µs and about 1 keV per channel.…”
Section: The Experimental Arrangementmentioning
confidence: 99%
“…The gamma-gamma coincidence method [4][5][6] has advantages in achieving the low Compton background and identifying the correlated gamma transitions. The advantages not only improve the detection limit gamma transition from (n,γ) reaction but also provide information of state, from which secondary transition decays.…”
Section: Introductionmentioning
confidence: 99%
“…For this reason, wehave measured the gamma cascades of 172 Yb from 171 Yb(n,γ) 172 Yb reaction using the gammagamma coincidence spectrometer [5] with 10 times statistics higher than reported in ref [7], for the aim of improving knowledge of level scheme of 172 Yb.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, the gamma-gamma coincidence methods have been shown to give accurate determination of Se in geological sample in Dalat Nuclear Research Reactor [1], and the interference of other gamma rays at the energy of interest such as the 152 Eu, 181 Hf and 182 Ta lines which interfere with the detection of 75 Se were solved without the need for radiochemical separation. This work, we applied processes the same described in Reference [1], in order to [7] determine Se in environmental sample by gammagamma coincidence method.…”
Section: Introductionmentioning
confidence: 99%