Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2005
DOI: 10.1002/chin.200510276
|View full text |Cite
|
Sign up to set email alerts
|

Gallium(III) Corroles

Abstract: Organic chemistry Z 0200Gallium (III) Corroles -[25 refs.]. -(WEAVER, J. J.; SORASAENEE, K.; SHEIKH, M.; GOLDSCHMIDT, R.; TKACHENKO, E.; GROSS, Z.; GRAY, H. B.; J.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 1 publication
1
5
0
Order By: Relevance
“…The energy gap measured between the 0-0 peaks observed in the absorption spectrum and the high-energy emission is nil, indicating that this emission is indeed fluorescent. The presence of fluorescence (and phosphorescence) for 3 is perfectly consistent with the recently reported related Ga(Corro1e) complexes, which exhibit strong fluorescence at room temperature in fluid solution (24,25). In addition, weaker phosphorescence is depicted at 739 nm based on a larger energy gap between the 0-0 peak observed in the Q-bands and this emission maximum (4100 cm?).…”
Section: Energy Diagramsupporting
confidence: 90%
See 3 more Smart Citations
“…The energy gap measured between the 0-0 peaks observed in the absorption spectrum and the high-energy emission is nil, indicating that this emission is indeed fluorescent. The presence of fluorescence (and phosphorescence) for 3 is perfectly consistent with the recently reported related Ga(Corro1e) complexes, which exhibit strong fluorescence at room temperature in fluid solution (24,25). In addition, weaker phosphorescence is depicted at 739 nm based on a larger energy gap between the 0-0 peak observed in the Q-bands and this emission maximum (4100 cm?).…”
Section: Energy Diagramsupporting
confidence: 90%
“…For example, the 0‐0 Q bands are located at 578, 589 and 554 nm for Cu(TPP), Zn(TPP) and Pd(TPP) (in benzene), respectively (15). This is also true for the 5,10,15‐tris(pentafluoro‐phenyl)corrole absorbing at 602 nm (CH 2 Cl 2 ) (23), whereas the corresponding Ga III complex (as a pyridine adduct in CH 2 Cl 2 ) exhibits a 0‐0 Q band at 594 nm (24, 25).…”
Section: Resultsmentioning
confidence: 83%
See 2 more Smart Citations
“…In vitro investigations into HSA binding with drugs may provide insight into the pharmacokinetics of the reaction . To date, only a few reports about the binding behavior of corrole with HSA are available . In connection with our previous work on the nuclease activity of metal corrole , we here report the DNA‐binding, HSA interaction and nuclease‐like activity of an iron‐sulfonated corrole Fe–SC (Fig.…”
Section: Introductionmentioning
confidence: 83%