2017
DOI: 10.1007/s11095-017-2214-3
|View full text |Cite
|
Sign up to set email alerts
|

Galactosyl Pentadecene Reversibly Enhances Transdermal and Topical Drug Delivery

Abstract: Galactosyl pentadecene A15 is a potent enhancer with low toxicity and reversible action.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
37
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(41 citation statements)
references
References 39 publications
4
37
0
Order By: Relevance
“…For the measurement, the tips of measuring probes were immersed in donor and in acceptor chamber, both lled with PBS buffer pH 7.4. 36 Skin samples with determined impedance above 3 kU were used in the permeation experiments. These values were similar to the electrical resistance of human skin reported by others.…”
Section: Skin Electrical Impedancementioning
confidence: 99%
“…For the measurement, the tips of measuring probes were immersed in donor and in acceptor chamber, both lled with PBS buffer pH 7.4. 36 Skin samples with determined impedance above 3 kU were used in the permeation experiments. These values were similar to the electrical resistance of human skin reported by others.…”
Section: Skin Electrical Impedancementioning
confidence: 99%
“…Skin impedance was measured using an LCR 4080 meter (Conrad Electronic, Germany) operating in parallel mode at 120 Hz (kΩ error < 0.5%). To make the measurement, the tips of the probes were immersed in the donor and acceptor chambers lled with the PBS solution (Kopečná et al 2017). Membranes with an electrical resistance of >3 kΩ, corresponding to the resistance measured for human skin, were used in the study (Davies et al 2004).…”
Section: Skin Permeation Studies Of Eugenol and New Estersmentioning
confidence: 99%
“…All donor chambers were closed with a plastic stopper to prevent excessive evaporation of the solution. The described tests were carried out for 24 hours, while 0.3 ml of the solution located in the acceptor chamber was taken at speci ed intervals (30 min, 1 h, 2 h, 3 h, 4 h, 5 h, 8 h and 24 h), and then supplemented with a fresh portion buffer at the same pH (Kopečná et al 2017). The samples were analyzed by high-performance liquid chromatography (HPLC) with a UV spectrophotometric detector (Knauer, Berlin, Germany).…”
Section: Skin Permeation Studies Of Eugenol and New Estersmentioning
confidence: 99%
“…For this purpose skin impedance was measured using an LCR 4080 meter (Conrad Electronic, Germany) operating in parallel mode at 120 Hz (kΩ error < 0.5%). To make the measurement, the tips of the probes were immersed in the donor and acceptor chambers filled with the PBS solution [34]. Membranes with an electrical resistance of >3 kΩ, corresponding to the resistance measured for human skin, were used in the study [35].…”
Section: Measurement Of the Antioxidant Capacity Of Cosmetic Formulatmentioning
confidence: 99%