Abstract: This study presents a wearable system that mainly consisted of piezoelectric sensors, filter circuit and data logger in order to measure the vertical ground reaction force (VGRF) and study its profile. The proposed system establishes base information to improve the portable gait analysis systems and make them easier in use also to be able to get more outdoor data. The experiments were done by a young healthy person without physical disabilities or nervous disorders and the experimental protocol was explained t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…And it would not be obvious in the sensor which was in perpendicular direction to the foot midline. On the other hand, the sensor in perpendicular direction to the foot midline senses the interface pressure clearly when compare its result to the data of same subject walking conditions at the force plate as shown in figure 6 [21,22]. The measured GRF with the force plate shows that the standard (M -shape) profile for the GRF, as the data from figure 6 represent the summation of the GRF from all the local sensors in the force plate under the foot print area.…”
Section: Resultsmentioning
confidence: 89%
See 4 more Smart Citations
“…And it would not be obvious in the sensor which was in perpendicular direction to the foot midline. On the other hand, the sensor in perpendicular direction to the foot midline senses the interface pressure clearly when compare its result to the data of same subject walking conditions at the force plate as shown in figure 6 [21,22]. The measured GRF with the force plate shows that the standard (M -shape) profile for the GRF, as the data from figure 6 represent the summation of the GRF from all the local sensors in the force plate under the foot print area.…”
Section: Resultsmentioning
confidence: 89%
“…This charging capability were sufficient to run the experiment for several hours to accomplish the required data collection protocols. In the end the collected data were stored and processed in a PC computer after transmitting through WiFi connection, the data then analysed to extract the gait cycle measurement [21,22].…”
Section: The Wearable Measurement Systemmentioning
confidence: 99%
See 3 more Smart Citations