2008
DOI: 10.1109/mpe.2008.927475
|View full text |Cite
|
Sign up to set email alerts
|

Gaining a Wider Perspective

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(10 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…The PMUs provide synchronized, real-time phasor measurements of voltage and current, generally augmented by measurement of frequency, rate of change of frequency, power and potentially other indirect measurements. PMUs providing such information have been used for different power system applications such system stability analysis, state estimation and wide area monitoring and control [1] [2].…”
Section: B Advanced Monitoring and Controlmentioning
confidence: 99%
“…The PMUs provide synchronized, real-time phasor measurements of voltage and current, generally augmented by measurement of frequency, rate of change of frequency, power and potentially other indirect measurements. PMUs providing such information have been used for different power system applications such system stability analysis, state estimation and wide area monitoring and control [1] [2].…”
Section: B Advanced Monitoring and Controlmentioning
confidence: 99%
“…Power/frequency disturbances tend to produce system wide clues and often opportunities to observe the propagation of the disturbance across the entire network [17]. Wide area monitoring using PMUs is accurate and globally synchronized.…”
Section: Wide Area Monitoring and Controlmentioning
confidence: 99%
“…All the SIPS actions can be performed faster and more accurately by using PMU data in a wide area network rather than state estimated data. Wide area control addresses automatic healing capabilities by proposing decisive smart topology changes and control actions with the goal of maintaining the integrity of the grid under imminent, adverse conditions [17]. …”
Section: Wide Area Monitoring and Controlmentioning
confidence: 99%
“…Today's power systems operate closer to their security limits and have become more sensitive to failure occurrence due to a number of factors such as; the continuous growth in the electricity consumption, the environmental and the economic constraints for building up new transmission lines together with the growing number of independent power generators increasing the power systems generation (as a result of the deregulation and restructuring processes in the electric industry worldwide) [1][2][3][4][5]. Thus, the use of new technologies for the implementation of control actions as well as new control schemes have had to be considered with the aim of ensuring a secure and reliable operation of the power systems [1][2][3][4][5], turning the daily operation of today´s power systems more complex than ever before [6].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the use of new technologies for the implementation of control actions as well as new control schemes have had to be considered with the aim of ensuring a secure and reliable operation of the power systems [1][2][3][4][5], turning the daily operation of today´s power systems more complex than ever before [6]. In this context, inter-area modes or low frequency oscillations in power systems have emerged as an important problem for secure system operation.…”
Section: Introductionmentioning
confidence: 99%