2013
DOI: 10.11591/ijece.v3i2.2262
|View full text |Cite
|
Sign up to set email alerts
|

Fuzzy PI Controllers Performance on Boost Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…From Figure 17, the actual current is still tracking its reference despite disturbance presence. Although current control for the proposed converter in this paper has been designed using a simple PI controller, it is possible to implement a more sophisticated method such as fuzzy controller [26], [27].…”
Section: Experimental Results Of the Proposed Convertermentioning
confidence: 99%
“…From Figure 17, the actual current is still tracking its reference despite disturbance presence. Although current control for the proposed converter in this paper has been designed using a simple PI controller, it is possible to implement a more sophisticated method such as fuzzy controller [26], [27].…”
Section: Experimental Results Of the Proposed Convertermentioning
confidence: 99%
“…To design a digital controller by direct digital design method, first, it needs to transform continuoustime model of ACFC into Discrete time Model [14] and then need to design a digital controller directly in the digital domain by using matched pole zero method. With the help of matched pole-zero method continuous model of ACFC is transformed in to digital form.The Discrete-time Transfer functions of ACFC are shown in (13)(14)(15)(16)(17)(18)). The designed discrete-time model of ACFC is very suitable to design the digital controller directly by using Root locus technique.…”
Section: Direct Digital Design Methodsmentioning
confidence: 99%
“…From the above results, it is observed that we are able to get zero voltage regulation but again to improve performance of the converter two loop controllers are required [15][16][17]. Authors are presented a paper [15] to design a two loop controller for Forward Converter with the active clamp circuit.…”
Section: Two-loop Controllermentioning
confidence: 99%
“…From the above results, it is observed that we are able to get zero voltage regulation but again to improve performance of the converter two loop controllers are required [15][16][17]. Authors are presented a paper [15] to design a two loop controller for Forward Converter with the active clamp circuit.…”
Section: Two-loop Controllermentioning
confidence: 99%