2012
DOI: 10.1007/s00521-012-0862-0
|View full text |Cite
|
Sign up to set email alerts
|

Fuzzy logic-based induction motor protection system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…Fuzzy systems are very useful in situations involving complex systems whose behaviours are difficult to model mathematically and are subject to uncertainties. A fuzzy system attempts to understand a system for which no model exists by implementing human experiences and preferences via fuzzy rules [56,57]. The authors in [56] use fuzzy logic to compute the optimal time delay required following fault occurrence in an induction motor.…”
Section: Artificial Intelligence (Ai) Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Fuzzy systems are very useful in situations involving complex systems whose behaviours are difficult to model mathematically and are subject to uncertainties. A fuzzy system attempts to understand a system for which no model exists by implementing human experiences and preferences via fuzzy rules [56,57]. The authors in [56] use fuzzy logic to compute the optimal time delay required following fault occurrence in an induction motor.…”
Section: Artificial Intelligence (Ai) Methodsmentioning
confidence: 99%
“…A fuzzy system attempts to understand a system for which no model exists by implementing human experiences and preferences via fuzzy rules [56,57]. The authors in [56] use fuzzy logic to compute the optimal time delay required following fault occurrence in an induction motor. The time delay depends on the level of the measured parameter or combination of the parameters that include under-and over-voltage, overcurrent, temperature rise, voltage and current unbalance.…”
Section: Artificial Intelligence (Ai) Methodsmentioning
confidence: 99%
“…References [2,3] suggest using fuzzy logic to put a delay between 0 and 4.5 s depending on the error type. If the fault is not recovered after this waiting time, stopping of the motor should be considered.…”
Section: Literature Review For Fuzzy Logic Controller Based Overcurre...mentioning
confidence: 99%
“…To achieve this, both devices (the one controlling and the one being controlled) must be embedded systems. They must have the ability to process data, and to communicate so that internet of things (IOT) can be implemented [7].…”
Section: Introductionmentioning
confidence: 99%