1992
DOI: 10.1103/physrevc.46.991
|View full text |Cite
|
Sign up to set email alerts
|

Fusionlike processes in theN14+232

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

1993
1993
2004
2004

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 55 publications
0
6
0
Order By: Relevance
“…Perhaps, the experimental approach most widely used has been the determination of the fission-fragment folding angle (127,(181)(182)(183)(184)(185)(186)(187)(188)(189)(190)(191)(192) in reactions induced by an intermediate energy heavy ion on a rather fissionable target, lil<e Au, Thor U. The distribution of folding angles typically shows two peaks, one close to 180°, characteristic of grazing collisions, and another, very broad, at a smaller angle.…”
Section: Incomplete Momentum Transfer Incomplete Fusion and Fireballmentioning
confidence: 99%
“…Perhaps, the experimental approach most widely used has been the determination of the fission-fragment folding angle (127,(181)(182)(183)(184)(185)(186)(187)(188)(189)(190)(191)(192) in reactions induced by an intermediate energy heavy ion on a rather fissionable target, lil<e Au, Thor U. The distribution of folding angles typically shows two peaks, one close to 180°, characteristic of grazing collisions, and another, very broad, at a smaller angle.…”
Section: Incomplete Momentum Transfer Incomplete Fusion and Fireballmentioning
confidence: 99%
“…Leegte et al [29] come to a somewhat similar conclusion on the basis of rather different arguments. They compare angle-integrated spectra with coalescence model spectra The decrease in complex particle to proton multiplicity with decreasing impact parameter observed in our work as illustrated in Fig.…”
Section: B Comparison With Other Experimentsmentioning
confidence: 86%
“…In recent years a number of large arrays using plastic and/or CsI scintillators have been built for heavy ion experiments [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16]. While these arrays offer a relatively inexpensive way of covering large solid angles, the nonlinear response of various scintillators as a function of the incident particle's energy, charge, and mass poses a challenge in their calibration.…”
Section: Introductionmentioning
confidence: 99%
“…While some authors have applied these models to their data [23,24], many others have used empirical expressions which may not be generally applicable [4,6,9,10,[25][26][27][28][29][30].…”
Section: Introductionmentioning
confidence: 99%