2019
DOI: 10.1016/j.jocn.2018.11.040
|View full text |Cite
|
Sign up to set email alerts
|

Fusion rate following three- and four-level ACDF using allograft and segmental instrumentation: A radiographic study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
54
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(63 citation statements)
references
References 17 publications
3
54
1
Order By: Relevance
“…For 3 and 4-level ACDF, higher pseudarthrosis rates were observed [Table 3]. [12,19] Lee et al . (2019) looked at fusion rates for 1-level vs. multilevel ACDF using polyetheretherketone (PEEK) cage-plate fusions in 57 patients followed at least 6 months [Table 3].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For 3 and 4-level ACDF, higher pseudarthrosis rates were observed [Table 3]. [12,19] Lee et al . (2019) looked at fusion rates for 1-level vs. multilevel ACDF using polyetheretherketone (PEEK) cage-plate fusions in 57 patients followed at least 6 months [Table 3].…”
Section: Introductionmentioning
confidence: 99%
“…(2019) also retrospectively evaluated fusion and pseudarthrosis rates for 72 patients undergoing 3 and 4-level ACDF (232 levels fused) [Table 3]. [19] Pseudarthrosis was observed at 47 (14%) total levels, with 45.8% of patients (33/72) exhibiting at least one level that failed to fuse (e.g. typically, the most caudal level).…”
Section: Introductionmentioning
confidence: 99%
“…The main indication of multilevel ACDF dued to symptomatic multilevel cervical degenerative disc disease with radiculopathy or myelopathy with strict and accurate re ection of neuro-dysfunction on body-dominating area [3,12]. Whether through ACP or SLC system, 3-level ACDF have been proved reliable and effective on decompression, stability and rebuilding of alighment, especially with the more advanced operating-skill and consequently extended sugical-indications on CSM [13]. The newer launched SLC was approved by some researchers for its zero-pro le design, simple inplanation, probable fewer comlications such as dysphagia contrasted to former-born ACP system.…”
Section: Discussionmentioning
confidence: 99%
“…In contrast, pseudarthrosis or implant failure most commonly occurs at the caudal level. 6,15,16 This can be explained by increased shear stress at the level near the cervicothoracic junction. 23 However, the ALOD risk is relatively low at the distal adjacent segment, which emphasizes the need for additional stability at the caudal level, whereas there is less need to increase plate-disc space distance.…”
Section: Discussionmentioning
confidence: 99%
“…9,10 Furthermore, pseudarthrosis or implant failure most commonly occur at the caudal-most level. 6,15,16 Therefore, we attempted a hybrid construct using xed screws at the caudal-most instrumented level and variable screws at the cranial and middle levels to prevent ALOD at the proximal adjacent level while minimizing the pseudarthrosis rate at the caudal level. This selective…”
Section: Introductionmentioning
confidence: 99%