2019
DOI: 10.1109/tsg.2017.2737359
|View full text |Cite
|
Sign up to set email alerts
|

Fusion of Multirate Measurements for Nonlinear Dynamic State Estimation of the Power Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 50 publications
(20 citation statements)
references
References 23 publications
0
17
0
1
Order By: Relevance
“…Aunque el objetivo de estos trabajos está dirigido a la a fusión multisensor, los modelos presentados son un claro ejemplo de la sinergia entre datos faltantes y MF. También destacan, trabajos que combinan los datos de medición de todos los sensores que utilizan algoritmos especiales para la fusión de datos multisensor (Nwe y Tun, 2017;Ghosal y Rao, 2019). Salt et al (2008) introducen lineamientos de los SMNC para ofrecer alternativas referente a los Sistemas de Control Basados en Red (NCS: Networked Control Systems) con el propósito de atender el desfase entre los muestreadores de las partes remota y local, cuando se requiere su sincronización.…”
Section: E1-4unclassified
“…Aunque el objetivo de estos trabajos está dirigido a la a fusión multisensor, los modelos presentados son un claro ejemplo de la sinergia entre datos faltantes y MF. También destacan, trabajos que combinan los datos de medición de todos los sensores que utilizan algoritmos especiales para la fusión de datos multisensor (Nwe y Tun, 2017;Ghosal y Rao, 2019). Salt et al (2008) introducen lineamientos de los SMNC para ofrecer alternativas referente a los Sistemas de Control Basados en Red (NCS: Networked Control Systems) con el propósito de atender el desfase entre los muestreadores de las partes remota y local, cuando se requiere su sincronización.…”
Section: E1-4unclassified
“…Synchronous multi-sensor systems have been investigated in the literature [37], [38]. However, only a few works discuss asynchronous systems, including sensors with various sampling rates [39], [40]. A multi-rate multiple sensors fusion method is developed in [41].…”
Section: A Literature Reviewmentioning
confidence: 99%
“…When a large number of DERs are connected to the distribution network, SCADA cannot effectively solve the DER access control problem. This is mainly because the SCADA has a low sampling density, remote terminal unit (RTU) data upload rate is low, often in the range of 0.5-2 frames/s [22], and the clocks of the stations are not uniform, resulting in inconsistent data time sections, an inaccurate system operation status [23], failures of the traditional radiation current protection scheme of the distribution network [24], a limited state estimation accuracy [25], and other issues. From the perspective of the protocol, since the IEC 60870-5-101/104 protocol does not include synchronization time and phasor data, the data time accuracy is not high, and the voltage phasor accuracy obtained by iteratively solving other measurement information is difficult to guarantee.…”
Section: Active Distribution Network Business Traffic Demandmentioning
confidence: 99%
“…From the perspective of application, whether all the information is needed in different application scenarios needs to be considered. For example, the master station needs all data to improve the accuracy of SCADA data [22,33]. However, for the hierarchical-distributed protection and control of the active distribution network, control units of each area or layer only need to acquire the synchronized phasor data to start the corresponding protection, and do not need to obtain all the information [8,34].…”
Section: Protocols Comparisonmentioning
confidence: 99%