Encyclopedia of Analytical Chemistry 2011
DOI: 10.1002/9780470027318.a9184
|View full text |Cite
|
Sign up to set email alerts
|

Fundamentals and Practical Aspects of Nonspectroscopic Interferences in Inductively Coupled Plasma Atomic Spectrometry

Abstract: Inductively coupled plasma atomic emission spectrometry (ICP/AES) and inductively coupled plasma mass spectrometry (ICP/MS) are well‐established techniques for elemental analysis. However, matrix effects can be considered to be their main pitfall. Changes in the performance of the system induced by the main sample component (or matrix) are referred to as matrix effects . As a result, the concentration obtained does not correspond to the actual one. Therefore, this is a problem that shou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 179 publications
0
2
0
Order By: Relevance
“…These conditions were chosen as extractor medium for the proposed procedure. The use of diluted HNO 3 is desirable in analytical methods based on ICP-optical emission spectrometry because does not affect the sample introduction system of the spectrometer and can overcome non-spectral interferences caused by eventual transport effects (Stewart & Olesik, 1998;Todolí & Mermet, 2011). In addition, diluted solutions contribute to environmental-friendly methods, following Green Analytical Chemistry recommendations (Bizzi et al, 2017).…”
Section: ( ) ( ) (mentioning
confidence: 99%
“…These conditions were chosen as extractor medium for the proposed procedure. The use of diluted HNO 3 is desirable in analytical methods based on ICP-optical emission spectrometry because does not affect the sample introduction system of the spectrometer and can overcome non-spectral interferences caused by eventual transport effects (Stewart & Olesik, 1998;Todolí & Mermet, 2011). In addition, diluted solutions contribute to environmental-friendly methods, following Green Analytical Chemistry recommendations (Bizzi et al, 2017).…”
Section: ( ) ( ) (mentioning
confidence: 99%
“…9–12 Commonly used methods for elemental content detection include wavelength dispersive X-ray fluorescence spectroscopy (WD-XRF), atomic absorption spectroscopy (AAS), inductively coupled plasma techniques (ICP-MS, ICP-OES), etc. 13–16 Although the above methods have remarkable detection sensitivity and accuracy, almost all of them target a single analytical index and involve complicated, time-consuming, and laborious sample preparation. Therefore, a rapid, simple pretreatment process and multi-element simultaneous detection method for petroleum coke analysis is required.…”
Section: Introductionmentioning
confidence: 99%