2005
DOI: 10.1007/s10439-005-2495-2
|View full text |Cite
|
Sign up to set email alerts
|

Fundamental Study of Ultrasonic-Measurement-Integrated Simulation of Real Blood Flow in the Aorta

Abstract: Abstract-Acquisition of detailed information on the velocity and pressure fields of the blood flow is essential to achieve accurate diagnosis or treatment for serious circulatory diseases such as aortic aneurysms. A possible way to obtain such information is integration of numerical simulation and color Doppler ultrasonography in the framework of a flow observer. This methodology, namely, Ultrasonic-Measurement-Integrated (UMI) Simulation, consists of the following processes. At each time step of numerical sim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
39
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 37 publications
(39 citation statements)
references
References 27 publications
0
39
0
Order By: Relevance
“…The subject (a 62-yearold male patient with a chronic aortic aneurysm in his descending aorta), as well as the measurement devices and method [an ultrasound device (SONOS 5500, Philips Medical Systems, Andover, MA, USA) with a trans-esophageal ultrasonic transducer (T6210, Philips Medical Systems, Andover, MA, USA)] in this study were the same as those in the former work (15) . Ultrasonic measurement was carried out with a color Doppler imaging technique from inside the esophagus.…”
Section: Subject and Measurement Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The subject (a 62-yearold male patient with a chronic aortic aneurysm in his descending aorta), as well as the measurement devices and method [an ultrasound device (SONOS 5500, Philips Medical Systems, Andover, MA, USA) with a trans-esophageal ultrasonic transducer (T6210, Philips Medical Systems, Andover, MA, USA)] in this study were the same as those in the former work (15) . Ultrasonic measurement was carried out with a color Doppler imaging technique from inside the esophagus.…”
Section: Subject and Measurement Methodsmentioning
confidence: 99%
“…Secondly, for feedback formula B, the effect of feedback gains (K v , K p ) on momentum and pressure equations is investigated. In the former study (15) , for the sake of simplicity, limited conditions K v = K p were investigated. In the present study, however, the optimum combination of the multiple feedback gains is investigated by changing them in two-dimensional parameter space.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations