Fundamental Spectral Boundaries of Circadian Tunability

Abstract: The discovery of melanopsin and the non-visual impact of light, lead to a new era in lighting design. Using a melanopic action spectrum, the CIE introduced the melanopic efficacy of luminous radiation (MELR), which quantifies the influence of light on melanopsin. A significant amount of research has been conducted on the possible variation of this MELR and other related metrics for various practical lighting settings, but the fundamental spectral boundaries have not yet been disclosed. Without these limits, it… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 39 publications
(37 reference statements)
2
3
0
Order By: Relevance
“…Figure 6 also shows that as the color fidelity floor is raised (i.e., from R f ≥ 70 to R f ≥ 80 to R f ≥ 90), the mean and spread of achievable mel-DER values decrease at any single CCT. This is consistent with the results of Carpentier and Meuret 39 . (Note that when color fidelity is maximal—i.e., IES TM-30 R f = 100—the ranges shown in Fig.…”
Section: Resultssupporting
confidence: 94%
See 1 more Smart Citation
“…Figure 6 also shows that as the color fidelity floor is raised (i.e., from R f ≥ 70 to R f ≥ 80 to R f ≥ 90), the mean and spread of achievable mel-DER values decrease at any single CCT. This is consistent with the results of Carpentier and Meuret 39 . (Note that when color fidelity is maximal—i.e., IES TM-30 R f = 100—the ranges shown in Fig.…”
Section: Resultssupporting
confidence: 94%
“…A clear trend between mel-DER and CCT is evident where, on average, mel-DER increases as CCT increases ( r 2 > 0.86). This trend is consistent with that demonstrated by Zandi et al 38 , Carpentier and Meuret 39 , and Spitschan 40 . Summary statistics are provided in Table 1 and can be used to estimate mel-DER for an SPD based on CCT and IES R f .…”
Section: Resultssupporting
confidence: 92%
“…When integrated with a camera, the PSFs can be fully characterized, and accurate tailoring can be achieved via least-squares calculation. 15 However, many illumination systems require a smooth irradiance pattern, in order to maximize visual comfort. This paper presents a preprocessing method of the target irradiance pattern for least-squares pixel activation, to ensure a smooth resulting illumination pattern.…”
Section: Discussionmentioning
confidence: 99%
“…This equation can be solved using the least-squares solution x = (A T A) −1 A T t. In reality, some calculated values may be negative, so a bounded-variable least-squares (BVLS) algorithm is used to find a solution with non-negative constraints on x. For a full, in-depth explanation, we refer to Cerpentier et al 15…”
Section: Base Proceduresmentioning
confidence: 99%
See 1 more Smart Citation