2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 2018
DOI: 10.1109/embc.2018.8512703
|View full text |Cite
|
Sign up to set email alerts
|

Functional Tasks Performed by People with Severe Muscular Atrophy Using an sEMG Controlled Robotic Manipulator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 17 publications
0
17
0
1
Order By: Relevance
“…Advances in biomedical devices have shown that some SMA-affected individuals may benefit from use of orthoses (externally applied devices designed to improve muscular function), such as robotic exoskeletons. These devices improve quality of life for people with muscular diseases [320][321][322][323][324], including SMA. One study demonstrated positive effects on range of motion and performance of daily living activities of SMA-affected individuals [322].…”
Section: Biomedical Devicesmentioning
confidence: 99%
“…Advances in biomedical devices have shown that some SMA-affected individuals may benefit from use of orthoses (externally applied devices designed to improve muscular function), such as robotic exoskeletons. These devices improve quality of life for people with muscular diseases [320][321][322][323][324], including SMA. One study demonstrated positive effects on range of motion and performance of daily living activities of SMA-affected individuals [322].…”
Section: Biomedical Devicesmentioning
confidence: 99%
“…Interfaces, which use the remaining capabilities of tetraplegics to generate signals suitable for proportional real-time control, may be based on neural activity [8,9], electromyography (EMG) [10,11], gaze [12], tongue movement [13], or head motion [14,15]. While all these solutions are generally feasible to enable robotic arm control, they might not be accessible to a subset of tetraplegic MS patients, due to the presence of interfering symptoms.…”
Section: Direct Control Interfaces For Tetraplegic Ms Patientsmentioning
confidence: 99%
“…Currently, the system can be interfaced either by a conventional joystick or alternatively by an interface based on electromyography (EMG). This EMG-based interface allows people to operate robotic systems continuously in 3D, when the use of a joystick is not an option due to the users impairment [19]. Furthermore, the system is equipped with an Asus Xtion Pro Live RGB-D camera to perceive the environment as well as an integrated head switch for additional user input.…”
Section: A System Descriptionmentioning
confidence: 99%
“…where the corresponding null space projector is denoted by N ∈ R 8×8 while J elbow ∈ R 6×8 and f elbow ∈ R 6 are the elbow Jacobian matrix and wrench, respectively. Similar to (19) the elbow wrench is calculated with a Cartesian stiffness and damping applied to the elbow frame. The forces that are applied to the mobile base are calculated by introducing end-effector-boundaries in which the platform motion should occur.…”
Section: A Whole-body Control Mode (Wbc)mentioning
confidence: 99%
See 1 more Smart Citation