Functional sensitivity of seven automated thyroid stimulating hormone immunoassays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…Representative total imprecision for these assays in our laboratory is as follows: TSH, 2.39% at 0.108 mIU/mL and 2.23% at 29.94 mIU/mL; FT4, 5.53% at 8.50 and 2.51% at 38.35 pmol/L, respectively; TT4, 4.17% at 58.95 and 3.20% at 208.11 nmol/L, respectively; TT3, 1.52% at 1.58 and 1.88% at 5.05 nmol/L, respectively; TPO-Ab, 7.57% at 0.72 mIU/mL and 2.98% at 84.21 IU/mL; and Tg-Ab 6.81% at 0.78 IU/mL and 1.95% at 156.99 IU/mL. Further performance characteristics of these assays have been previously described [13,14]. Data analysis was performed using AnalyseIt software, version 2.20 (Leeds, UK).…”
Section: Methodsmentioning
confidence: 97%
“…Representative total imprecision for these assays in our laboratory is as follows: TSH, 2.39% at 0.108 mIU/mL and 2.23% at 29.94 mIU/mL; FT4, 5.53% at 8.50 and 2.51% at 38.35 pmol/L, respectively; TT4, 4.17% at 58.95 and 3.20% at 208.11 nmol/L, respectively; TT3, 1.52% at 1.58 and 1.88% at 5.05 nmol/L, respectively; TPO-Ab, 7.57% at 0.72 mIU/mL and 2.98% at 84.21 IU/mL; and Tg-Ab 6.81% at 0.78 IU/mL and 1.95% at 156.99 IU/mL. Further performance characteristics of these assays have been previously described [13,14]. Data analysis was performed using AnalyseIt software, version 2.20 (Leeds, UK).…”
Section: Methodsmentioning
confidence: 97%
“…At the laboratory-scale, performance quality should be assessed to ensure agreement with the performance announced by the manufacturer. Indeed, studies have reported discordances between the manufacturers' claims and the laboratory assessment [5,6]. Consequently, when Siemens optimized the TSH3 and FrT4 assays to produce the new and improved TSH3-ultra (TSH3-UL) and FT4 assays, we assessed the key analytical performance characteristics of the new assays on the ADVIA Centaur immunoassay system in a multicenter national evaluation.…”
Section: Introductionmentioning
confidence: 99%
“…Assay testing was performed by chemiluminescent immunoassay on the Abbott ARCHITECT analyzer (Abbott Laboratories, Abbott Park, IL, USA) according to manufacturer's instructions. The principles of this instrument system and performance characteristics for these assays have been previously described [12][13][14][15]. Manufacturer's cut-off values for Anti-TPO ( < 5.6 IU/mL) and Anti-Tg ( < 4.11 IU/ mL) were used.…”
Section: Methodsmentioning
confidence: 99%