2006
DOI: 10.2170/physiolsci.rp004506
|View full text |Cite
|
Sign up to set email alerts
|

Functional Residual Capacity and Airway Resistance of the Rat Measured with a Heat- and Temperature-Adjusted Body Plethysmograph

Abstract: Abstract:The functional residual capacity (FRC) and airway resistance (R aw ) of the rat were measured, using a newly designed body plethysmograph (BPG), the inner environment of which was maintained at body temperature and was water-vapor saturated. The subjects were anesthetized and tracheally intubated male Wistar rats (n = 15). After measuring the FRC and R aw , we analyzed the effects of inhaled methacholine (Mch, 0-8 mg/ml) on R aw .The determined FRC was 5.37 ± 0.22 ml (mean ± SE). An almost linear rela… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…The experiment-specific tidal volume and breathing rate are those discussed above derived from measured data, the MPPD defaults are, respectively, 2.1 mL and 102 min ¡1 . The FRC of Wistar rats has been measured and reported in a number of papers (Tazaki et al 2006;Tajiri et al 2006;Filho et al 2014). The most relevant study is that of Filho et al (2014), which measured body weight and lung volumes and capacities of over 240 Wistar rats from 2 to 24 months.…”
Section: Deposition Modelingmentioning
confidence: 99%
“…The experiment-specific tidal volume and breathing rate are those discussed above derived from measured data, the MPPD defaults are, respectively, 2.1 mL and 102 min ¡1 . The FRC of Wistar rats has been measured and reported in a number of papers (Tazaki et al 2006;Tajiri et al 2006;Filho et al 2014). The most relevant study is that of Filho et al (2014), which measured body weight and lung volumes and capacities of over 240 Wistar rats from 2 to 24 months.…”
Section: Deposition Modelingmentioning
confidence: 99%
“…Our previous BPG [6,7] was a sealed box with a capacity of 1,950 ml. Approximately 1,800 ml of water circulated around the box, and the water was warmed or cooled by electronic elements with 240 W power.…”
Section: Precision Of the Systemmentioning
confidence: 99%
“…We recently reported the applicability of the body plethysmograph (BPG) for estimation of obstructive changes in small animals [6], permitting the simultaneous measurement of airway resistance (R aw ) and lung volume [6,7]. Transiently maintaining gases in the BPG at BTPS (body temperature, atmospheric pressure and water vapor saturated), we measured R aw in rats without requiring any special maneuver or assumptions [6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation