2016
DOI: 10.1371/journal.pone.0152267
|View full text |Cite
|
Sign up to set email alerts
|

Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies

Abstract: IntroductionPatients with acute respiratory distress syndrome (ARDS) typically show a high degree of ventilation inhomogeneity, which is associated with morbidity and unfavorable outcomes. Electrical impedance tomography (EIT) is able to detect ventilation inhomogeneity, but it is unclear which method for defining the region of interest (ROI) should be used for this purpose. The aim of our study was to compare the functional region of interest (fROI) method to both the lung area estimation method (LAEM) and no… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 25 publications
0
20
0
Order By: Relevance
“…Its application during the resuscitation phase respectively the initial operation period and during following intensive care treatment may improve outcome by real-time diagnosis and prompt adaptation of treatment, e.g. by avoiding abnormal distension of primarily unaffected lung sections6566. As a growing number of clinical studies implies establishment of EIT under diverse medical conditions67, we are certain that this method, once provided in the trauma setting, will help to detect time-displaced lung dysfunction also in trauma patients that suffer from consequences of indirect damage to the lung caused by remote injuries, and multiple organ failure or sepsis.…”
Section: Discussionmentioning
confidence: 99%
“…Its application during the resuscitation phase respectively the initial operation period and during following intensive care treatment may improve outcome by real-time diagnosis and prompt adaptation of treatment, e.g. by avoiding abnormal distension of primarily unaffected lung sections6566. As a growing number of clinical studies implies establishment of EIT under diverse medical conditions67, we are certain that this method, once provided in the trauma setting, will help to detect time-displaced lung dysfunction also in trauma patients that suffer from consequences of indirect damage to the lung caused by remote injuries, and multiple organ failure or sepsis.…”
Section: Discussionmentioning
confidence: 99%
“…One subgroup describes the overall degree of spatial heterogeneity of ventilation. Examples are the global inhomogeneity index36 40 49 or the coefficient of variation,36 42 50 calculated from the maps of tidal impedance variation. Another subgroup describes the orientation of the spatial distribution of functional measures, usually in the anteroposterior direction.…”
Section: Eit Measuresmentioning
confidence: 99%
“…Determining the lung regions from static volume CT during inspiratory hold did not capture the movement in thoracic shape, lung and heart regions caused by tidal ventilation. Here, a combination of the presented method with other evaluation methods to assess moving lung borders or functional ROI methods [ 35 ] might be a valuable extension to our analysis. Other potential sources of errors are the choice of tissue property weighting (e.g., for lungs and heart) [ 36 ] and the exclusion of bones and other tissue properies in the FEMs, but a complete evaluation was beyond the scope of this work.…”
Section: Discussionmentioning
confidence: 99%