2017
DOI: 10.1002/admt.201600251
|View full text |Cite
|
Sign up to set email alerts
|

Fully Printed Electrodes on Stretchable Textiles for Long‐Term Electrophysiology

Abstract: International audienceFully printed electrodes consisting of a conducting polymer and an ionic liquid gel are fabricated on a stretchable textile. They are shown to record cardiac activity while the wearer is moving and for long periods of time, paving the way for the development of low-cost devices for continuous health monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
91
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 90 publications
(92 citation statements)
references
References 15 publications
1
91
0
Order By: Relevance
“…The conductivity of polymers relies on the delocalization of electrons and the doping process along π‐bonded conjugated backbone, which allows them to be both electronic and ionic conductor. Their high transconductance facilitates biosignal transduction from the cell to the recording electrode . PPy NWs/PPy film electrode shows a lower impedance than bare Au or PPy/Au electrode, high stretchability (≈100%), and high interfacial adhesion (1.9 MPa) (Figure f) .…”
Section: Stretchable and Conformal Sensors For Cyber Biophysical Intementioning
confidence: 99%
See 1 more Smart Citation
“…The conductivity of polymers relies on the delocalization of electrons and the doping process along π‐bonded conjugated backbone, which allows them to be both electronic and ionic conductor. Their high transconductance facilitates biosignal transduction from the cell to the recording electrode . PPy NWs/PPy film electrode shows a lower impedance than bare Au or PPy/Au electrode, high stretchability (≈100%), and high interfacial adhesion (1.9 MPa) (Figure f) .…”
Section: Stretchable and Conformal Sensors For Cyber Biophysical Intementioning
confidence: 99%
“…The polymeric microelectrode arrays are successfully applied in differentiating a normal rat from epileptic rat by in vivo recording electrocorticograph (ECoG) signals and stimulating the rat ischiadic nerve . Besides, polyaniline, polythiophene derivatives such as PEDOT:PSS are also well‐established for electreophysiological signals. One more thing to be considered is the toxic residual monomers or oligomer and stability of electroactive polymers which might be adverse for constructing biocompatible interfaces …”
Section: Stretchable and Conformal Sensors For Cyber Biophysical Intementioning
confidence: 99%
“…In fact, many studies have examined flexible and stretchable sensors to monitor health data [1][2][3][4][5][6][7][8] such as skin temperature, [9][10][11] electrocardiogram (ECG), [12][13][14][15][16][17] chemical contents in the body through sweat, [18][19][20][21][22][23] and activity. [24,25] These demonstrations are steps toward future wearable multifunctional flexible electronic devices by further developing into a system with improved reliability.…”
Section: Introductionmentioning
confidence: 99%
“…Conventional electrodes are wet electrodes that include gels to improve adhesion onto the skin and resist external environmental factors; however, with time, dehydration of the gel causes decreasing signal quality, increasing signal noise, and skin irritation. Extensive research is attempting to solve these issues [2,4,6,[16][17][18][19][20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%