2020
DOI: 10.1186/s13005-020-00241-3
|View full text |Cite
|
Sign up to set email alerts
|

Fully-customized distraction assembly for maxillofacial distraction osteogenesis: a novel device and its experimental accuracy verification

Abstract: Background A new distraction osteogenesis assembly system comprising a fully customized CAD/CAM-based fixation unit and ready-made distraction unit was developed. The aim of this study was to introduce our new distraction system and to evaluate its accuracy level in a sampled mandibular distraction osteogenesis. Methods Our system consists of a fully customized CAD/CAM-based fixation plate unit with two plates for each moving and anchoring part, and a ready-made distraction unit with attachment slots for fixa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 20 publications
(22 reference statements)
0
4
0
Order By: Relevance
“…In another study of mandibular DO on the standard mandibular 3D printed phantoms, a series of new fully customized distraction assemblies were developed, including the individualized 3D printed titanium footplate, customized driver screw, and the CAD/CAM splint for guiding the former two devices into position. The linear deviations of the distraction results demonstrated the proposed assembly's accuracy ( 15 ). On the contrary, these linear deviations in this study were smaller.…”
Section: Discussionmentioning
confidence: 78%
See 1 more Smart Citation
“…In another study of mandibular DO on the standard mandibular 3D printed phantoms, a series of new fully customized distraction assemblies were developed, including the individualized 3D printed titanium footplate, customized driver screw, and the CAD/CAM splint for guiding the former two devices into position. The linear deviations of the distraction results demonstrated the proposed assembly's accuracy ( 15 ). On the contrary, these linear deviations in this study were smaller.…”
Section: Discussionmentioning
confidence: 78%
“…The internal distractor vector control is a major concern in DO ( 14 ). The effect of virtual surgical planning (VSP) combined with CAD/CAM splints has been demonstrated in several studies ( 15 17 ). However, the virtual footplates could not be contoured to conform to the 3D models, and the requirement of strong 3D visualization capabilities increased the difficulty of establishing the required vectors of movement during the VSP procedure ( Figure 7 ) ( 18 , 19 ).…”
Section: Discussionmentioning
confidence: 99%
“…83 Using this device, in conjunction with a CAD guide, resulted in significantly improved distraction accuracy compared to conventional devices when performed on 3D-printed microsomic mandibles. 83…”
Section: Mandiblementioning
confidence: 92%
“…81,82 Kang et al recently created a fully customized device using computer-aided design/computer-aided manufacturing (-CAD/CAM) with customized plates that are contoured to match the mandibular bone surface for improved distractor position and maintenance of the vector. 83 Using this device, in conjunction with a CAD guide, resulted in significantly improved distraction accuracy compared to conventional devices when performed on 3D-printed microsomic mandibles.…”
Section: Current Mandibular Distraction Techniquementioning
confidence: 92%