2021
DOI: 10.1016/j.talanta.2020.121923
|View full text |Cite
|
Sign up to set email alerts
|

Fully automated method for quantitative determination of steroids in serum: An approach to evaluate steroidogenesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 56 publications
0
7
0
Order By: Relevance
“…On-line SPE has been published frequently for steroids in combination with tandem mass spectrometry [19] , [20] , [21] . This shows the increasing importance of this technique in the field of laboratory medicine where it is already used for endocrinological diagnostics [22] , [23] , [24] .…”
Section: Discussionmentioning
confidence: 99%
“…On-line SPE has been published frequently for steroids in combination with tandem mass spectrometry [19] , [20] , [21] . This shows the increasing importance of this technique in the field of laboratory medicine where it is already used for endocrinological diagnostics [22] , [23] , [24] .…”
Section: Discussionmentioning
confidence: 99%
“…The sensitivity of the assay was 5 pg/tube for LH and 20 pg/tube for FSH. In addition, sex steroid levels were measured in serum samples using a previously validated, sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, adapted from protocols described in detail elsewhere (Luque-Cordoba and Priego-Capote 2021). Determinations of estradiol (E 2 ), testosterone (T), dihydro-testosterone (DHT) and progesterone (P) were conducted in control and TaKKO mice of both sexes, at 4-weeks and 2-months of age.…”
Section: Methodsmentioning
confidence: 99%
“…More importantly, estrogens can be only monitored under the negative ion mode during direct analysis. To achieve adequate sensitivity, ammonium fluoride should be introduced into the mobile phase in many cases. However, even under neutral conditions, fluoride anions can degrade silica-based stationary phases cause continuous column bleeding and prevent buffer switching during daily usage. , Besides, during heating and ionizing in the ion source, ammonium fluoride will produce hydrofluoric acid, , which may induce erosion to the instrument . Recently, in a pair of progressive contributions, an unexplained decrease (about 50-fold) of sensitivity for estradiol detection has been rigorously reported by Häkkinen’s group after enrolling ammonium fluoride in the mobile phase for 1 year. , …”
Section: Introductionmentioning
confidence: 99%