2014
DOI: 10.1063/1.4892480
|View full text |Cite
|
Sign up to set email alerts
|

Fully automated dual-frequency three-pulse-echo 2DIR spectrometer accessing spectral range from 800 to 4000 wavenumbers

Abstract: A novel dual-frequency two-dimensional infrared instrument is designed and built that permits three-pulse heterodyned echo measurements of any cross-peak within a spectral range from 800 to 4000 cm(-1) to be performed in a fully automated fashion. The superior sensitivity of the instrument is achieved by a combination of spectral interferometry, phase cycling, and closed-loop phase stabilization accurate to ~70 as. The anharmonicity of smaller than 10(-4) cm(-1) was recorded for strong carbonyl stretching mode… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
41
0
2

Year Published

2015
2015
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(43 citation statements)
references
References 42 publications
0
41
0
2
Order By: Relevance
“…137139 New approaches for detection and data acquisition are being devised to continuously improve data quality and access different observables 25. 87, 140144…”
Section: Discussionmentioning
confidence: 99%
“…137139 New approaches for detection and data acquisition are being devised to continuously improve data quality and access different observables 25. 87, 140144…”
Section: Discussionmentioning
confidence: 99%
“…[40][41][42] Figure 6 shows an example dual frequency spectrum of methylglycolate that covers the entire fingerprint region of the infrared. 43 It was formed by combining a series of narrow region spectra. The dynamic range in this spectrum is >10 5 and is normalized by the magnification to the brightest feature in each cluster of peaks.…”
Section: Dual Frequency Cmdsmentioning
confidence: 99%
“…[33,[137][138][139] Neue Verfahren für die Detektion und Datenerfassung werden entwickelt um die Datenqualität zu verbessern und um Zugang zu neuen Observablen zu erhalten. [25,87,[140][141][142][143][144] 2D-IR-Spektren zeigen viele Details der molekularen Welt, dementsprechend müssen die theoretischen Methoden, die die Interpretation der Spektren stützen, sehr leistungsfähig sein. Dies gilt umso mehr für die hier diskutierten 2D-Spektroskopien, die auch elektronisch angeregte Zustände und starke Abweichungen vom Gleichgewicht beinhalten.…”
Section: Zusammenfassung Und Ausblickunclassified
“…Verbesserungender Hardware haben schon jetzt durch erhçhte Stabilitätu nd Automatisierung dieA nwendung vereinfacht. [25,144,145] Fürd ie reinenI R-Pulssequenzen gibt es bereits Messaufbauten, diev on Nichtspezialisten gehandhabt werden kçnnen.E rste kommerziell erhältliche 2D-IR-Spektrometer, welches ogar dieI mplementierung von gemischtenPulssequenzenerlauben, finden ihren Wegauf den Markt. [145,146] Wirs indd aher zuversichtlich, dassd ie Anzahl derW issenschaftler, died ie Mçglichkeitend er hierv orgestellten mehrdimensionalen Experimente nutzenk çnnen (direkto derü berd ie Zusammenarbeit mit einers pezialisierten Arbeitsgruppe), in naherZukunfterheblichwachsenwird.…”
Section: Zusammenfassung Und Ausblickunclassified