Full-Wave Analysis of Dielectric-Loaded Cylindrical Waveguides and Cavities Using a New Four-Port Ring Network

Abstract: Penaranda-Foix, FL.; Janezic, MD.; Catalá Civera, JM.; Canós Marín, AJ. (2012). Full-wave analysis of dielectric-loaded cylindrical waveguides and cavities using a new four-port ring network. IEEE Transactions on Microwave Theory and Techniques. 60(9):2730-2740. doi:10.1109/TMTT.2012.2206048. > REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK HERE TO EDIT) < 1 Abstract-In this paper, a full-wave method for the electromagnetic analysis of dielectric-loaded cylindrical and coaxial waveguide… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
33
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 33 publications
(35 citation statements)
references
References 58 publications
(63 reference statements)
2
33
0
Order By: Relevance
“…To verify the accuracy of the dielectric calculations, a number of different samples in a wide range of dielectric constant and losses were machined in rods of 15-mm height and 9.8-mm diameter and measured inside quartz vials at room temperature by the CPM described above. The results were compared with measurements of the same samples, without the container, in a closed cylindrical cavity (diameter mm and height mm) solved by a rigorous mode-matching method [13]. The measured complex permittivities are tabulated in Table I.…”
Section: B Accuracy Of the Cpmmentioning
confidence: 99%
See 1 more Smart Citation
“…To verify the accuracy of the dielectric calculations, a number of different samples in a wide range of dielectric constant and losses were machined in rods of 15-mm height and 9.8-mm diameter and measured inside quartz vials at room temperature by the CPM described above. The results were compared with measurements of the same samples, without the container, in a closed cylindrical cavity (diameter mm and height mm) solved by a rigorous mode-matching method [13]. The measured complex permittivities are tabulated in Table I.…”
Section: B Accuracy Of the Cpmmentioning
confidence: 99%
“…The accuracy of dielectric measurements has been evaluated by comparing the results given by the CPM with a rigorous solution of the cylindrical cavity [13]. Experimental results of complex permittivity of ceramic and glass samples are given in Section V for temperatures varying from room temperature to 1000 C.…”
mentioning
confidence: 99%
“…The microwave dielectric values were measured, before sintering and once the samples were sintered, in a TM 0np cavity with the circuit analysis method as described in [25].…”
Section: Microwave Setupmentioning
confidence: 99%
“…network analyzer, a microwave amplifier, an infrared pyrometer and a computer were employed to carry out the measurement. The cylindrical rod shape sample was placed inside a quartz tube containers and microwave are applied for heating and measuring simultaneously inside a microwave cavity [10]. Typical uncertainty of these measurements is around 2% in real part and 5% in imaginary part.…”
Section: Characterizationmentioning