2019 IEEE International Ultrasonics Symposium (IUS) 2019
DOI: 10.1109/ultsym.2019.8925778
|View full text |Cite
|
Sign up to set email alerts
|

Full Wave 3D Inverse Scattering Transmission Ultrasound Tomography: Breast and Whole Body Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 21 publications
0
14
0
Order By: Relevance
“…With the rapid development of 3D breast ultrasound imaging device, ultrasound array with thousands of elements has been fabricated recently. 36 Another advantage for XACT to be an in vivo dosimetry is its potential to be combined with anatomical ultrasound imaging. The B-mode ultrasound images and the radiation-induced signals can be obtained by the same transducer.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…With the rapid development of 3D breast ultrasound imaging device, ultrasound array with thousands of elements has been fabricated recently. 36 Another advantage for XACT to be an in vivo dosimetry is its potential to be combined with anatomical ultrasound imaging. The B-mode ultrasound images and the radiation-induced signals can be obtained by the same transducer.…”
Section: Discussionmentioning
confidence: 99%
“…The physical radius of the 3D hemispherical transducer array is 7.2 cm, and each sensor has an area of 5.71 mm 2 to receive the acoustic signal. With the rapid development of 3D breast ultrasound imaging device, ultrasound array with thousands of elements has been fabricated recently 36 . Another advantage for XACT to be an in vivo dosimetry is its potential to be combined with anatomical ultrasound imaging.…”
Section: Discussionmentioning
confidence: 99%
“…In 2017, another breast ultrasound tomograph system using a combination probe of a pair of 2D array probes and three linear probes was built in QT Ultrasound, LLC, CA, USA and was issued by FDA a 510K alliance. Because they used both low and high frequency signals, a high quality sound speed image can be reconstructed [3].…”
Section: Introductionmentioning
confidence: 99%
“…While waveform inversion is the clinical in vivo gold standard for obtaining high-resolution diagnostic-quality images of the speed of sound in tissue, 11,12 it remains unclear to what extent the starting model for the sound speed profile in the medium impacts the solution of waveform inversion. In a ring array geometry, a refractioncorrected bent ray tomography is often used in ultrasound tomography to obtain a starting model prior to waveform inversion.…”
Section: Introductionmentioning
confidence: 99%