2022
DOI: 10.1038/s41598-022-04969-7
|View full text |Cite
|
Sign up to set email alerts
|

Full scale tests of various buried flexible structures under failure load

Abstract: The aim of the tests described in the paper was conducting a displacement and stress analysis of four buried flexible structures made in different technologies under failure load. Generally, the laboratory tests carried out on in full scale confirms that all four culvert models of the work safely despite the reduction of the backfill layer over the structures to 0.3 m (less than according to standard recommendations) and increasing the load to 1960 -2000 kN (almost 4 times more than according to standards and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 14 publications
(12 reference statements)
0
2
0
Order By: Relevance
“…Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076, India. * email: dc@civil.iitb.ac.in; dchoudhury@iitb.ac.in to different loading condition including traffic loading is also assessed by performing field test and full-scale laboratory test 10,11 . However, underground utilities (pipe, culvert) can be protected from external live loads such as traffic loads or loads generated from permanent ground deformation by providing suitable barrier system.…”
Section: Openmentioning
confidence: 99%
See 1 more Smart Citation
“…Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076, India. * email: dc@civil.iitb.ac.in; dchoudhury@iitb.ac.in to different loading condition including traffic loading is also assessed by performing field test and full-scale laboratory test 10,11 . However, underground utilities (pipe, culvert) can be protected from external live loads such as traffic loads or loads generated from permanent ground deformation by providing suitable barrier system.…”
Section: Openmentioning
confidence: 99%
“…With increasing soil cover depth initial bending moment of the pipe was increased due to soil weight but moment due to traffic load was significantly reduced. The behaviour of buried culvert subjected to different loading condition including traffic loading is also assessed by performing field test and full-scale laboratory test 10 , 11 . However, underground utilities (pipe, culvert) can be protected from external live loads such as traffic loads or loads generated from permanent ground deformation by providing suitable barrier system.…”
Section: Introductionmentioning
confidence: 99%
“…Wysokowski [96] conducted full-scale tests of various buried soil steel composite structures under failure load, namely, PE plastic pipe, corrugated steel pipe, box culvert, and multi-plate elliptical structure. Displacements and stresses were investigated under failure load.…”
Section: Ultimate Load-carrying Capacity Of Sscsmentioning
confidence: 99%