2000
DOI: 10.1016/s0950-0618(00)00008-8
|View full text |Cite
|
Sign up to set email alerts
|

Full-scale testing of a parking structure column retrofitted with carbon fiber reinforced composites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2003
2003
2024
2024

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 55 publications
(18 citation statements)
references
References 3 publications
0
15
0
Order By: Relevance
“…FRP retrofitting of circular or rectangular columns with inadequate lap-splices of ribbed (deformed) bars with straight ends has been studied by Chang et al [2001], Elnabelsy and Saatcioglu [2004], Harries et al [2003], Haroun et al [2001], Laplace et al [2005], Ma et al [1997Ma et al [ , 2000, Restrepo, et al [1998], , , Saatcioglu and Elnabelsy [2001], Schlick and Brena [2004], and Xiao and Ma [1997].…”
mentioning
confidence: 99%
“…FRP retrofitting of circular or rectangular columns with inadequate lap-splices of ribbed (deformed) bars with straight ends has been studied by Chang et al [2001], Elnabelsy and Saatcioglu [2004], Harries et al [2003], Haroun et al [2001], Laplace et al [2005], Ma et al [1997Ma et al [ , 2000, Restrepo, et al [1998], , , Saatcioglu and Elnabelsy [2001], Schlick and Brena [2004], and Xiao and Ma [1997].…”
mentioning
confidence: 99%
“…A large number of studies have been conducted to assess the impact of CFRP strengthening on the general behavior and failure modes of the strengthened RC columns. Ma et al [24] reported that deficient RC columns retrofitted with external CFRP jacketing exhibited stable flexural response with improved ductility and energy dissipation capacity by preventing brittle shear failure. Similarly, Ye et al [25] found that shear strength of the RC column with inadequate transverse reinforcement can be improved with the CFRP sheets.…”
Section: Cfrp Strengtheningmentioning
confidence: 99%
“…Cantilever columns have been extensively tested in the past (Priestley et al 1992, Saadatmanesh et al 1996, Saadatmanesh et al 1997b, Saadatmanesh et al 1997a, Seible et al 1997, Xiao and Ma 1997, Haroun et al 1999, Ma and Xiao 1999, Chang et al 2000, Ma et al 2000, Chang et al 2001, Saatcioglu and Elnabelsy 2001, Haroun et al 2003, Elnabelsy and Saatcioglu 2004, Sause et al 2004, Schlick and Breña 2004, Yalçin and Kaya 2004, Bousias et al 2006, Bousias et al 2007, Breña and Schlick 2007, Youm et al 2007, Chung et al 2008, Eshghi and Zanjanizadeh 2008, Harajli 2008, ElGawady et al 2010, Bournas and Triantafillou 2011, Kim et al 2011. Column specimens are usually cast on a stiff concrete block simulating the structure's foundation, as shown in Figure 1.…”
Section: Capacity-ductility Approach: Tests On Cantilever Columnsmentioning
confidence: 99%