2013
DOI: 10.1007/s10162-013-0394-z
|View full text |Cite
|
Sign up to set email alerts
|

Full-Field Thickness Distribution of Human Tympanic Membrane Obtained with Optical Coherence Tomography

Abstract: The full-field thickness distribution, three-dimensional surface model and general morphological data of six human tympanic membranes are presented. Crosssectional images were taken perpendicular through the membranes using a high-resolution optical coherence tomography setup. Five normal membranes and one membrane containing a pathological site are included in this study. The thickness varies strongly across each membrane, and a great deal of interspecimen variability can be seen in the measurement results, t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

11
100
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 124 publications
(112 citation statements)
references
References 34 publications
11
100
1
Order By: Relevance
“…Our data and TM preparations are consistent with both of the numerical constraints: The thickness of the human TM varies between 50 and 140 lm (Van der Jeught et al, 2013), and the largest displacements we observe are <3 lm, which leads to a displacement to thickness ratio of <0.06.…”
Section: E Does the Tm Act As A Thin Shell?supporting
confidence: 88%
“…Our data and TM preparations are consistent with both of the numerical constraints: The thickness of the human TM varies between 50 and 140 lm (Van der Jeught et al, 2013), and the largest displacements we observe are <3 lm, which leads to a displacement to thickness ratio of <0.06.…”
Section: E Does the Tm Act As A Thin Shell?supporting
confidence: 88%
“…The vibration magnitude is obtained in radians (rad) and then is converted to nanometers (nm) by multiplying the magnitude data with λ o /(4nπ), where λ o is the center wavelength of the laser light source and n is the sample refractive index. The refractive index of the tympanic membrane was assumed to be 1.44 [25].…”
Section: Data Processingmentioning
confidence: 99%
“…The goal was to characterize the relationship between the intensity of the excitation signal and the sound pressure level (SPL) generated by the speaker for multiple frequencies. A circular film with a thickness of 0.05 mm and a diameter of 1/2" was prepared to mimic the size of the adult TM, which has a thickness on the order of 0.05 to 0.12 mm and diameter of on the order of 8 to 10 mm [25]. As the surface of the film is covered with the acrylate adhesive, the film was self-adhesively tightened on a half inch-diameter optical mount.…”
Section: Instrument Optimizationmentioning
confidence: 99%
“…6(d) shows the surface image of the TM and the A-line obtained from a point on the TM, marked by a red asterisk in the inset. The thickness of the TM (assuming a refractive index of 1.4 for the TM [17]) was estimated to be 106 µm, which lies in the range of thickness values expected for a healthy TM [17][18][19][20].…”
Section: Methods and Resultsmentioning
confidence: 99%