Full Field Digital Mammography (FFDM) versus CMOS Technology, Specimen Radiography System (SRS) and Tomosynthesis (DBT) - Which System Can Optimise Surgical Therapy?

Abstract: Aim: This prospective clinical study aimed to evaluate whether it would be possible to reduce the rate of re-excisions using CMOS technology, a specimen radiography system (SRS) or digital breast tomosynthesis (DBT) compared to a conventional full field digital mammography (FFDM) system. Material and Method: Between 12/2012 and 2/ 2013 50 patients were diagnosed with invasive breast cancer (BI-RADS™ 5). After histological verification, all patients underwent breast-conserving therapy with intraoperative imagin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 32 publications
0
4
0
1
Order By: Relevance
“…If standard control mammography (two orthogonal planes, cranio-caudal and medio-lateral oblique views) is done after stereotactic vacuum biopsy with clip marking [9], the question arises whether it is possible to detect dislocation of an intramammary marker clip after ultrasound-guided core needle biopsy with clip placement. Based on our previous experience [11][12][13][14] with intramammary clip marking systems, the aim of our current study was to investigate the accuracy of sonography and digital breast tomosynthesis to determine the location of intramammary marker clips placed in small breast cancers with diameters of less than 2 cm (cT1).…”
Section: Comparison Of Sonography Versus Digital Breast Tomosynthesismentioning
confidence: 99%
“…If standard control mammography (two orthogonal planes, cranio-caudal and medio-lateral oblique views) is done after stereotactic vacuum biopsy with clip marking [9], the question arises whether it is possible to detect dislocation of an intramammary marker clip after ultrasound-guided core needle biopsy with clip placement. Based on our previous experience [11][12][13][14] with intramammary clip marking systems, the aim of our current study was to investigate the accuracy of sonography and digital breast tomosynthesis to determine the location of intramammary marker clips placed in small breast cancers with diameters of less than 2 cm (cT1).…”
Section: Comparison Of Sonography Versus Digital Breast Tomosynthesismentioning
confidence: 99%
“…Although DBT is now widely used in screening and diagnostic imaging, it is not routinely used for specimen imaging. Some studies have shown increased sensitivity with single view DBT specimen imaging and improved performance of DBT in lesion size assessment [14,26]. Chagpar et al also found that intraoperative DBT of the specimen led to a slight reduction in re-excision rate [27].…”
Section: Discussionmentioning
confidence: 99%
“…In diesen Fällen kann die Tomosynthese, eine 3D-Mammografie, hilfreich sein (▶ Abb. 4) [11]. Durch eine im 15-Grad-Winkel schwenkende Röntgenröhre entstehen Schichtaufnahmen in verschiedenen Projektionen, die eine 3D-Darstellung der Brust ermöglichen.…”
Section: Tomosyntheseunclassified